Optional Step: Connect to the SpO2
To connect and attach the SpO2 probe to Apollo:
a. Locate the SPO2 port on Apollo's left hip.
b. Connect the SpO2 probe to the SPO2 port.
c. Place the SpO2 probe on Apollo.
Optional Step: Connect External Air
Using the External Air kit allows Apollo to be run by an external air source rather than the internal
compressor. The air hose can be connected to or disconnected from Apollo at any time. When the
external air pressure is sensed, the pump internal to Apollo turns off automatically. When you want
to make Apollo mobile again, simply disconnect the hose.
The optional External Compressed Air Kit consists of a flexible 30 ft (9 m) hose attached to a preset air
regulator and a fitting for air compressors and adapters for wall or tank air.
To connect the air hose:
a. Connect the External Compressed Air Kit to a CAE compressor using the
Quick Coupler attached to the regulator. (Other compressed air sources
have their own adapters. Locate the adapter for your compressed air
source.).
b. Connect the other end of the External Compressed Air Kit to the EXTERNAL
AIR port on the left shoulder.
Optional Step: Insert CO
To insert the CO
canister:
2
a. Lift the chest skin at the waist and lift the abdominal insert.
b. From the simulator's right midsection, remove the pull pin and disconnect
the blue CO
2
c. Remove the regulator from the simulator.
d. While holding the regulator firmly, carefully twist the CO
regulator as far as it will go. The final turns puncture the CO
which is necessary for correct operation.
CAUTION: Do not loosen the canister once it has been inserted into the regulator
assembly until the contents are exhausted and pressure relieved.
Removing the canister before it is empty results in the sudden release of all high-pressure
gas with a possibility of liquid CO
e. Place the CO
pull pin to secure this assembly to the tray. A properly installed assembly
will have the CO
©2021 CAE 905K351052 v1.1
2
hose.
spray. Unprotected skin could receive freezing burns.
2
canister, regulator and hoses inside the simulator. Use the
2
canister pointed down toward the rear of the simulator.
2
Canister (Prehospital Only)
canister into the
2
2
Setup
canister,
31