3.10.2.2 Zone
Short press with bottom rotary knob will display subpage Zone, where setting for default
parameters of point zone: start, turn point and finish sector can be set.
Selecting any of displayed options, the following list of parameters is displayed.
Turn-point – cannot be modified and is set as default.
Type - describes zones specifications or directions.
o Symmetrical
o Fixed
o To next
o To previous
o To start
A21 – angle between leg and rotation of observer zone
A1 – will determine the zone angle.
R1 – will determine the zone radius.
A2 – will add secondary angle to zone.
R2 – will add secondary radius to zone.
Line – will enable feature only edge border of zone is shown.
With all set parameters, you can now preview zone with selection of View feature.