Camshaft Replacement - Pentair AUTOTROL MAGNUM 293 Installer Manual

Table of Contents

Advertisement

Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Maintenance
9.6.8

Camshaft replacement

1. Remove the camshaft cover (1). See Camshaft cover disassembly [
2. Press on the release tab
ð The front end of the camshaft will be flush with the mounting plate (6).
3. Loosen the four screws
4. Remove the two pillow blocks
5. Remove the camshaft (4).
6. Reverse above procedure steps to rebuild.
Info
When reassembling the camshaft (4), place it through the mounting plate (6). Rotate
the cam assembly counter-clockwise until the camshaft arrow
block arrow (11). Then engage the camshaft with the controller.
80 / 110
(9)
and pull on the back end of the camshaft (2).
(3)
and (5).
(7)
and (8).
Page 78].
(10)
aligns with pillow
Ref. MKT-IM-012 / D - 03.02.2022