Wiring Instructions - enphase CLIPPERCREEK ACS User Manual

Table of Contents

Advertisement

ACS User Manual

WIRING INSTRUCTIONS

Route the ACS conduit to a nearby junction box. Use the included
¼" trade size watertight conduit fitting and sealing washer to
provide a moisture-resistant seal between the conduit fitting
and the junction box. If necessary, drill a 1/2" diameter hole to
accommodate the conduit fitting or use the included 1/4" NPT to
1/2" NPT thread reducer kit. For outdoor installations, ensure the
junction box is fully sealed using appropriate electrical grade
silicone sealant.
Figure 6: Wiring the ACS in a Junction Box
NOTE: Before connecting the ACS
service conductors, please carefully
read the section of this manual titled
Installation - Service Connections. If
unsure of the type of power provided
at the service panel, please consult
with the local utility or call a Service
Representative for assistance.
NOTE: The three ACS service
conductors use stranded 12 AWG, 75ºC
copper wire. The insulation of each
conductor is color coded for standard
120V AC installation:
Green: Ground
Black: Line 1 (120V AC to Ground)
White: Neutral
Page 26