Electrical Installation
23
Signal Outputs
Name
Terminal
OUT1
TBO.1 3-4
OUT2
TBO.1 5-6
OUT3
TBO.1 7-8
OUT4
TBO.1 9-11
OUT5
TBO.1 12-13
TBO.1 13-14
OUT6
TBO.3 1-2
OUT7
TBO.3 3-4
OUT8
TBO.2 11-12
OUT9
TBO.2 9-10
OUT11
TBO.2 1-2
OUT12
TBO.2 3-4
OUT13
TBO.2 7-8
BC
TBO.3 5-6
OUT10
TBO.1 1-2
BHT
TBO.2 13-14
Notes
1. Do not connect multiple high power water circulation pumps directly to each output (OUT1, OUT2, and OUT3).
In such a case, connect them via (a) relay(s).
2. Connect an appropriate surge absorber to OUT10 (TBO.1 1-2) depending on the load at site.
(continued)
Connector Function
-
Pump 1 (CH & DHW)
-
Pump 2 (CH zone 1)
-
Pump 3 (CH zone 2)
-
2 way valve 1
-
Mixing valve
-
Mixing valve
-
Boost heater 1
-
Boost heater 2
-
Boost heater 2+
CNIH
Immersion heater
-
Error output
-
Defrost output
-
2 way valve 2
-
Boost heater
protection
-
Boiler output
CNBHT
Thermostat for boost
heater
Pre-Plumbed Slimline Cylinder Installation Manual
OFF
ON
Signal/Max
Current
OFF
ON
230V AC 1A Max
OFF
ON
230V AC 1A Max
OFF
ON
230V AC 1A Max
Heating
DHW
230V AC 0.1A Max
Stop
Close
230V AC 0.1A Max
Stop
Open
230V AC 0.1A Max
OFF
ON
230V AC 0.5A Max
(relay)
OFF
ON
230V AC 0.5A Max
(relay)
OFF
ON
230V AC 0.5A Max
(relay)
230V AC 0.5A Max
(relay)
Normal
Error
230V AC 0.5A Max
(relay)
Normal
Defrost
230V AC 0.5A Max
(relay)
DHW
Heating
230V AC 0.1A Max
OFF
ON
230V AC
(BHT
(BHT
0.5A Max
open)
closed)
(relay)
OFF
ON
Non voltage contact
*220-240V AC (30V
DC) 0.5A or less
*10mA 5V DC or
more
Thermostat Normal:
short/ High temp:
open
-
Max
Total
Current
3 A (a)
3 A (b)
-
-