1.4 Technical specifications of drive
The main specifications of Q2BYG808MD/Q2BYG806DK are shown in the
following table:
Control technology
Input power supply
Overvoltage protection point
Undervoltage protection point
Phase current (A) (808MD)
Phase current (A) (806DK)
Number of subdivisions
Basic
Dimensions
specifications
Conditions of
Use
Instruction
Input signal
pulse
Q2BYG808MD Driver User's Manual
Advanced space vector control
technology
Single power supply 40~100VAC
(808MD)
Single power supply 40~100VAC
(806DK)
160VDC (808MD) / (806DK)
40VDC (808MD) / (806DK)
2.0, 3.0, 3.5, 4.0, 4.2, 5.2, 5.6, 6.2
1, 2, 4, 8, 16, 32, 64, 128, 256, 5, 10,
25, 50, 100, 200
144×102×48.5mm
Operating
/
storage
45℃/‐20℃~55℃
temperature
Operating
/
40%~80%/0%~90%
storage
condensation)
humidity
Degree
of
IP10
protection
Resistance to
vibration
/
4.9m/s2/19.6 m/s2
shock
Altitude
<1000m, derate if above 1000m
Atmospheric
86~106kpa
pressure
1. Pulse + direction
Pulse species
2. Pulse + pulse
3. A + B 90 ° quadrature pulse
1. Differential drive
Pulse shape
2. Open collector
Pulse
1. Differential drive: 500K
frequency
2. Open collector: 200K
-8-
(no
Need help?
Do you have a question about the Q2BYG806DK and is the answer not in the manual?