Chapter 2 Installation
2.1 Installation of stepper drive
2.1.1 Installation environment conditions
The environment for stepper drive installation has a direct impact on the
normal operation and life of the drive, so the drive installation environment
must meet the following requirements:
Operating environment: temperature: 0 ~ 45℃; humidity: 40%~80% (no
condensation);
Storage environment: temperature: ‐40~55℃; humidity: < 90% (no
condensation);
Vibration: < 0.5G;
Prevent raining and humid environment;
Avoid direct sunlight;
Prevent oil mist and salt erosion;
Keep away from corrosive liquid and gas;
Prevent dust, cotton, and small metal filings;
Keep away from radioactive and flammable objects;
When several drives are installed in the control cabinet, retain sufficient
space to help the flow of air; to help cooling, please install a fan to reduce
the temperature around the drive; to ensure long‐term safety, the
operating temperature should be 45℃;
If there is unavoidable vibration source nearby, use vibration absorber or
install anti‐vibration pad to avoid transmitting the vibration to the drive;
When interference is mixed in power supply circuit of input signal, it is
easy to cause drive malfunction. If interference may be mixed, take
appropriate measures, such as adding a noise filter and a variety of other
anti‐jamming measures, to ensure the normal operation of the drive.
(Note that the leakage current will increase if noise filter is added. In order
Q2BYG808MD Driver User's Manual
-10-
Need help?
Do you have a question about the Q2BYG806DK and is the answer not in the manual?