jbc CDEB Instruction Manual page 6

Soldering-assistant station
Hide thumbs Also See for CDEB:
Table of Contents

Advertisement

Changing the Grips
Replace the grips easily using the slip-on tabs. Note: Choose the correct grip depending on your handle
-Q:
model.
Handle ref.: T245-A / T245-C / T245-GA
Grip ref.:
1. Inserting Tabs
tabs
new grip
Put the slide-on tabs into the
new grip.
Sealing Plug Replacement
The sealing plug prevents undesirable flux vapors or particles from entering inside the tool. Its usage
is highly recommended for intensive applications when soldering is exposed to FOD environments or
for applications where the soldering iron works close to vertical position. Note: Choose the correct
sealing plug depending on your handle model.
Handle ref:
Sealing plug ref.:
Before replacing the sealing plug, unplug the power supply and make sure the device is not hot.
1. Removing Sealing Plug
Enter, not deeper than 8mm,
a small shaft or screwdriver,
lift and pull the sealing plug.
Never use a cartridge to do
this operation.
6
0016057 (green)
2. Inserting Handle
Push the grip with the tabs
onto the handle.
T245 / T470
OB2000
2. Mounting Position
Sealing
Plug
Handle
Note: The chamfered side has
to be positioned towards the
handle.
T210-A / T210-NA
0018658 (green)
T210
OB1000
T245-PA
T210-PA
0021528 (blue)
0023310 (blue)
3. Removing Tabs
Hold the grip and pull the tab.
Use pliers if necessary.
3. Inserting Sealing Plug
Push the sealing plug inside
the handle until the sealing
plug and handle edges are
aligned.