General Settings
Parameter Description
Temp units
Celsius (ºC) or Fahrenheit (ºF)
Date&Time
Set the Date and the Time.

Port Settings

Parameter Description
Cartridge
Select the cartridge.
Temp adjust
It provides a more precise
adjustment between the
selected temperature and the
actual one.
Temp level set
Similar to "Fix one temp"
parameter. In this case, the
user can set up to 3 values for
different power requirements.
14
Recommendations
Recommendations
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends
the use of TID-A or TIA-A
Thermometers to obtain
precise readings.
This allows a quick change
between 3 different tempe-
ratures. Set them according
to the allowed values for your
soldering applications.
Warnings
Warnings
When the user changes
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartridge.
E.g. If a correction of
+20°C (+36°F) is set for the
C245966 (thick type) and
then the user changes the
cartridge for a C245030
(which is thinner) without
resetting, they would be
working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.