Installation & Operations Guide - SmartSource Micro Elite IJ
Cleaning track sensors
The unit includes three sensors, as shown. If dirt or dust accumulates on these sensors, errors may result.
View shown with right cover and inner cover removed
Clean these sensors using canned or compressed air, or a soft cloth or cotton swap moistened with isopropyl alcohol.
Cleansing wipes pre-soaked with suitable solvent are available from the Digital Check Store, www.digitalcheck.com, part
number 75-1804-907.
Rev. D
This sensor pair resides low-the top about
3/8" above the metal base.
8227 5727-003
There are 2 pairs of sensors, one on each side of
the first roller-about 1" above the base plate.
The sensors look through the track gap.