Station Cos - Pgm 116 - LG-Ericsson iPECS eMG80 Programming Manual

Hide thumbs Also See for iPECS eMG80:
Table of Contents

Advertisement

iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
4.4.2.6

Station COS - PGM 116

Selecting Station COS will display the Station COS data input page. Enter a valid station range and click
[Load] to enter the Station COS data.Use the check mark to indicate which attributes to modify; data for
checked attributes is stored by clicking [Save] button.
In case of PGM 116 is in condition of limited service mode due to License issue, the default value is 7 for all
COS type.All stations are assigned a Class-of-Service (COS), which determines the ability of the user to dial
certain types of calls, refer to Table 4.4.2.6-1. Separate COS assignments are made for Day, Timed and Night
Mode operation. As a default all stations are assigned with a Station COS of 1 for all modes, no restrictions.
The station COS interacts with the CO Line COS to establish overall dialing or Toll restrictions. This interaction
and the resulting restrictions are given in Table 'Station/CO COS'.Long distance calls are determined by the
first dialed digit ("0" or "1") and the number of digits dialed. If the first digit dialed is a LD code, default "0" or
"1", or, if the number of digits dialed exceeds the assigned LD digit counter in 'System Data SMDR Attributes
section', the call is considered a Long Distance call and appropriate restrictions applied.
STATION
1
No restrictions are placed on dialing from the station.
2
The assignments in Exception Table A are monitored for allow and deny numbers.
3
The assignments in Exception Table B are monitored for allow and deny numbers.
4
The assignments in both Exception Tables A & B are monitored for allow and deny numbers.
The leading digit dialed cannot be a Long Distance code, default "0" or "1", and further
5
denied/allowed based on Exception Table C.
The leading digits dialed cannot be a Long Distance code & digit count cannotexceed the LD digit
6
counter, default 7 digits, and further denied/allowed based onException Table C.
Intercom and paging calls are allowed. No outgoing dialing except for emergency calls is allowed
7
on CO Lines.
8
The assignments in the Exception Table D are monitored for allow and deny numbers.
The assignments in the Exception Table E are monitored for allow and deny
9
Numbers
10
The assignments in the Exception Table D & E are monitored for allow and deny numbers.
The assignments in the Exception Table A & B and D & E are monitored for allow and deny
11
numbers.
Figure 4.4.2.6-1 Station COS
Table 4.4.2.6-1 STATION COS