STANDALONE MODE USING ADJUSTABLE STATIC DIMMING
In standalone mode, all four ports are treated as one group. Note: all switch settings can
be changed when the driver is off or on. To configure the Aqua Driver for standalone static
dimming you need to:
1 On the 10-way switch block, set switch 10 OFF to
choose standalone mode.
2 On the 6-way switch block, set switch 6 ON to
choose manual dimming mode.
1 On the 10-way switch block, use
switches 1 to 8 to choose the
dimming level (for all emitters
of every connected Aqua Graze
fixture). When all eight switches
are OFF, the fixtures will be at
0%; conversely, all switches
ON will produce 100% output.
The switches are arranged as a
binary byte, with switch 1 as the
least significant bit and switch 8
as the most significant.
16
Manual dimming mode: ON
Dimming level
LSB
1
2
3
4
www.acclaimlighting.com
Standalone mode: OFF
6
7
8
1
2
3
4
MSB
5
6
7
8
ON
9
10
ON
5
6
ON
9
10