Altronix Trove Mercury kits are pre-assembled and consist of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies.
These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
Altronix
Model Number
T2MK3F4D
–
3.5
T2MK3F4DQ
3.5
P
T2MK3F8D
–
3.5
T2MK3F8DQ
3.5
P
T2MK7F8D
–
4.5
T2MK7F8DQ
4.5
P
T2MK75F16D
–
8
T2MK75F16DQ
8
P
T2MK77F16D
–
9
T2MK77F16DQ
9
P
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product
is intended for indoor use only.
1. Remove backplane(s) from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper
screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes
and install the three fasteners. Place the enclosure's upper keyholes over the three upper screws. Install the three
lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite
hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side
(Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed
reporting device. To activate alarm signal open the door of the enclosure.
4. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB, eFlow102NB, eFlow104NB and
Sub-Assembly Installation Guide for the following models: ACM4CB, ACM8CB, LINQ2, PDS8CB, VR6 for
further installation instructions.
5. Fasten snap on spacers onto metal pems configuration of backplane depending on the Mercury access controller
(Fig. 2-5, pg. 3-6).
6. Position Mercury access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2-5, pg. 3-6).
7. Mount backplane to enclosure with hardware.
- 2 -
Configuration Chart:
Nominal DC Output Voltage
Power Supply
Power Supply
1
[DC] [Aux] [DC] [Aux]
5A/
10A/
20.19-
20.19-
250V
32V
26.4
26.4
5A/
10A/
20.19-
20.19-
250V
32V
26.4
26.4
5A/
10A/
20.19-
20.19-
250V
32V
26.4
26.4
5A/
10A/
20.19-
20.19-
250V
32V
26.4
26.4
6.3A/
15A/
20.17-
20.28-
250V
32V
26.4
26.4
6.3A/
15A/
20.17-
20.28-
250V
32V
26.4
26.4
6.3A/
250V 15A/
20.17-
20.28-
32V
26.4
26.4
5A/
250V
6.3A/
250V 15A/
20.17-
20.28-
32V
26.4
26.4
5A/
250V
6.3A/
15A/
20.17-
20.28-
20.17-
250V
32V
26.4
26.4
6.3A/
15A/
20.17-
20.28-
20.17-
250V
32V
26.4
26.4
Installation Instructions:
Overview:
2
Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
board and ACM4CB/
ACM8CB Access Power
Controller's
outputs
–
–
24VDC @ 5.8A
–
–
24VDC @ 5.8A
–
–
24VDC @ 5.8A
–
–
24VDC @ 5.8A
–
–
24VDC @ 9.2A
–
–
24VDC @ 9.2A
9.7-
10.03-
12VDC @ 9.3A
13.2
13.2
24VDC @ 9.2A
9.7-
10.03-
12VDC @ 9.3A
13.2
13.2
24VDC @ 9.2A
20.28-
24VDC @ 9.2A
26.4
26.4
20.28-
24VDC @ 9.2A
26.4
26.4
10A/
10A/
4
2.0
2A
250V
250V
10A/
10A/
4
2.0
2A
250V
250V
10A/
10A/
8
2.0
2A
250V
250V
10A/
10A/
8
2.0
2A
250V
250V
10A/
10A/
8
2.0
2A
250V
250V
10A/
10A/
8
2.0
2A
250V
250V
10A/
16
2.0
2A
250V
10A/
16
2.0
2A
250V
10A/
10A/
16
2.0
2A
250V
250V
10A/
10A/
16
2.0
2A
250V
250V
Enclosure
Edge of
Enclosure
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Trove2/Mercury PTC Kits Installation Guide
2A
–
2A
–
2A
–
2A
–
2A
–
2A
–
–
–
2A
–
–
2A
2A
–
2A
–
Fig. 1