Download Print this page
Altronix T2MK3F4D Installation Manual

Altronix T2MK3F4D Installation Manual

Advertisement

Quick Links

Access & Power Integration Solutions
Installation Guide for models:
T2MK3F4D
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) ACM4CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
T2MK3F4DQ
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (1) ACM4CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
T2MK3F8D
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
T2MK3F8DQ
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (1) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
T2MK7F8D
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
Rev. TMKD060117
Installing Company: __________________________ Service Rep. Name: ______________________________________________
Address: _______________________________________________________________ Phone #: ___________________________
T2MK7F8DQ
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (1) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
T2MK75F16D
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane and TMV2 door backplane
- (1) eFlow104NB and (1) eFlow102NB - Power Supply/Chargers
- (2) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PD8ULCB - Power Distribution Module
T2MK75F16DQ
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane and TMV2 door backplane
- (1) eFlow104NB and (1) eFlow102NB - Power Supply/Chargers
- (1) LINQ2 - Network Communications Module
- (2) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PD8ULCB - Power Distribution Module
T2MK77F16D
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane and TMV2 door backplane
- (2) eFlow104NB - Power Supply/Charger
- (2) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
T2MK77F16DQ
Fully assembled kit includes:
- Trove2 enclosure with TM2 backplane and TMV2 door backplane
- (2) eFlow104NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (2) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input Power Distribution Module
More than just power.™

Advertisement

loading
Need help?

Need help?

Do you have a question about the T2MK3F4D and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix T2MK3F4D

  • Page 1 Access & Power Integration Solutions Installation Guide for models: T2MK3F4D T2MK7F8DQ Fully assembled kit includes: Fully assembled kit includes: - Trove2 enclosure with TM2 backplane - Trove2 enclosure with TM2 backplane - (1) eFlow6NB - Power Supply/Charger - (1) eFlow104NB - Power Supply/Charger...
  • Page 2: Configuration Chart

    Overview: Altronix Trove Mercury kits are pre-assembled and consist of Trove2M2 enclosure with factory installed Altronix power supply/ charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
  • Page 3 T2MK3F4D: One (1) eFlow6NB - 24VDC @ 6A Power Supply/Charger, one (1) ACM4CB - 4 PTC output Access Power Controller, one (1) VR6 - 24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8CB - 8 PTC output Dual Input Power Distribution Module.
  • Page 4 8 PTC output Access Power Controller, one (1) VR6 - 24VDC input to 12VDC output Voltage Regulator, and one (1) PDS8CB - 8 PTC output Dual Input Power Distribution Module. LINQ2 Fig. 3 (T2MK7F8DQ) Altronix eFlow104NB Altronix ACM8CB Altronix PDS8CB & VR6 - 4 - T2MKD Kits...
  • Page 5 (1) LINQ2 Network Communication Module, two (2) ACM8CB - 8 PTC output Access Power Controller, and one (1) PD8ULCB - 8 PTC output Power Distribution Module. Fig. 4 LINQ2 (T2MK75F16DQ) Altronix PD8ULCB Altronix eFlow104NB Altronix eFlow102NB Altronix ACM8CB Altronix ACM8CB T2MKD Kits - 5 -...
  • Page 6 PTC output Access Power Controller, one (1) VR6 - 24VDC input to 12VDC output Voltage Regulator and one (1) PDS8CB - 8 PTC output Dual Input Power Distribution Module. Fig. 5 LINQ2 (T2MK77F16DQ) Altronix PDS8CB & VR6 Altronix eFlow104NB Altronix eFlow104NB Altronix ACM8CB Altronix ACM8CB - 6 - T2MKD Kits...
  • Page 7 Altronix Sub-Assemblies and/or Adapters: 1. Fasten nylon / snap on standoffs to pems which match the hole pattern for Altronix Sub-Assemblies (Fig. 6, 6a, pg. 7). 2. Mount boards to standoffs utilizing pan head screws provided with the product or by depressing board onto snap on standoff (Fig.
  • Page 8 (50.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. MEMBER IITrove2M2 Kit Series...

This manual is also suitable for:

T2mk7f8dqT2mk3f4dqT2mk75f16dT2mk3f8dT2mk75f16dqT2mk3f8dq ... Show all