Electrical Data
ECM Motor
Rated
Model
Voltage
115/60/1
09
208-230/60/1
265/60/1
115/60/1
12
208-230/60/1
265/60/1
208-230/60/1
15
265/60/1
208-230/60/1
18
265/60/1
HACR circuit breaker in USA only
Compressor
Voltage
Min/Max
MCC
RLA
104/127
12.5
8.0
187/253
6.4
4.1
238/292
6.7
4.3
104/127
14.8
9.5
187/253
7.7
4.9
238/292
7.0
4.5
187/253
9.2
5.9
238/292
7.8
5.0
187/253
10.4
6.7
238/292
8.7
5.6
33
RC SERIES ENGINEERING GUIDE
Fan
Total
Motor
Unit
LRA
FLA
FLA
50.0
4.25
12.3
21.0
2.6
6.7
22.0
2.5
6.8
50.0
4.25
13.8
25.0
2.6
7.5
22.0
2.5
7.0
29.0
2.6
8.5
28.0
2.5
7.5
33.5
2.6
9.3
28.0
2.5
8.1
Min
Max
Circ
Fuse/
Amp
HACR
14.3
20
7.7
10/15
7.9
10/15
16.1
25
8.8
10/15
8.1
10/15
10.0
15
8.8
10/15
10.9
15
9.5
15
1/20/14