Advertisement

Quick Links

Set-Up Information • Operator's Manual • Technical Information
#5600-RTS Alpha MUTT
Tablet and Slide-Out Base
#5600A-RT Alpha MUTT
Rugged Tablet
Innovative Products of America
ALPHA MUTT
Mobile Universal Trailer Tester
For All Models
with ABS, Rugged
®
with ABS and
®
Incorporated 234 Tinker Street, Woodstock, NY 12498
®
888-786-7899 | tech247@ipatools.com | www.ipatools.com
with ABS
®
#5600A-S Alpha MUTT
®
Slide-Out Base
#5602A Alpha MUTT
with ABS
®
(No Tablet or Slide-Out Base)
with ABS and

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALPHA MUTT and is the answer not in the manual?

Questions and answers

Summary of Contents for iPA ALPHA MUTT

  • Page 1 ALPHA MUTT with ABS ® Mobile Universal Trailer Tester Set-Up Information • Operator’s Manual • Technical Information For All Models #5600-RTS Alpha MUTT with ABS, Rugged #5600A-S Alpha MUTT with ABS and ® ® Tablet and Slide-Out Base Slide-Out Base...
  • Page 2 Congratulations on your recent purchase of an Alpha MUTT Service-Truck ® Model from Innovative Products of America ® This binder provides information on the following Alpha MUTT units: ® • #5602A Alpha MUTT with ABS ® • #5600A-RT Alpha MUTT with ABS and Rugged Tablet ®...
  • Page 3 • Recognize the safety precautions that should be adhered to during operation. • Properly identify all parts, accessories and attachments included with the tester for maintenance, operation, repair and replacement. truly wants you to be 100% satisfied with your purchase. The Alpha MUTT includes a 3-Year ®...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Part 1: Introduction Testing Functions ……………………...……………………………………....Registering Your Tester’s Warranty ……………….…………………......… Tester Identification ………………………………………………………...... Tester Serial Number Firmware Version Number Software Version Number Included Accessories ………………………...…….…………………......… Optional Accessories ……...……………………….………………......… Part 2: General Safety Instructions Important Safety Information ……………...…..…...………………......… Battery Gases, Tester Preparation and Tester/Charger Location …....….
  • Page 5 Part 7: Operating the Alpha MUTT ® Application Setup …………………………………………………………....……. Accounts Company Information Testing Defaults Menu Bar Screens …………………………………………………………....…… Diagnostic Controls …………………………………………………………...….. Part 8: Electrical/Lighting Testing Pretest Checklist …………………………………………………………...... Tester Placement Maintain Connectors Cable Testing Procedure Selecting a Circuit ……………………………………………………....………….
  • Page 6 Part 13: Maintenance 13.1 Maintenance and Storage ……………………………………......……. 13-1 13.2 Instructions for In- and Out-of-Warranty Repairs …………………......13-2 Part 14: Troubleshooting 14.1 FAQ ………………………………………………………………........14-1 14.2 Common System Checks …………………………………………......14-2 14.3 Common Troubleshooting Solutions ……………………………....... 14-3 Part 15: Exploded Views and Diagrams 15.1 Body Exploded View ………………………...............
  • Page 7: Part 1: Introduction Pg

    Part 1: Introduction...
  • Page 8: Testing Functions

    This manual covers the Alpha MUTT® Series technology. Please consult your specific model for your exact list of included options. This product is backed by a 3-year warranty with 24-hour repair or replace service.
  • Page 9: Registering Your Tester's Warranty

    (either by warranty card from the seller or by point of purchase receipt/invoice) and the manufacturer makes every attempt to return ship the product within three business days from the receipt of the returned product, freight prepaid. If it has been determined that the tool has been damaged due to misuse, IPA ®...
  • Page 10: Tester Identification

    Firmware Version Number The Firmware version number will display on the LCD Menu Screen when you power the tester on. Software Version Number Can be found on the top right corner of any screen while in the Alpha MUTT App. ®...
  • Page 11: Included Accessories

    1.4 Included Accessories Image Part # Description Location Included In 12-Button Remotes and Battery #MUT-RM12 Remote with All Models Accessories Nylon Bag Lanyard Docking Station Inside #5600A-RTS #5700-TABRT Rugged Tablet Storage Drawer #5600A-RT Mount for #5600A-RTS #5700-MNTRT-AS Inside Storage Drawer Rugged Tablet #5600A-RT Connected to Tablet...
  • Page 12: Optional Accessories

    1.5 Optional Accessories Image Part # Description Includes Optional For 50’ 7-Way Cable #7900K-1-50-AS All Alpha Models 50’ Gladhands with #5705-HS50 All Alpha Models Handles Rugged Tablet, #5600A-S Rugged Tablet Docking Station, #5600A-NT Upgrade Hardware #5600-NT Sliding-Base Sliding-Base #5600A-RT Service Tray Service Tray, #5600A-NT Upgrade...
  • Page 13: Part 2: General Safety Instructions

    Part 2: General Safety Instructions...
  • Page 14: Important Safety Information

    PART 2: GENERAL SAFETY INSTRUCTIONS 2.1 Important Safety Information It is important to read, understand and follow all safety messages and instructions printed in this manual and on the equipment before operating. If safety information is not heeded, serious injury or death to the operator or bystanders may occur.
  • Page 15: General Charger Usage

    • Clean terminals before charging battery. Keep corrosive particles from eyes, nose and mouth. Use baking soda and water to neutralize acid and help eliminate airborne corrosion. • Never allow clamps on charger cables to touch each other. • Do not expose tester or charger to rain, snow or wet conditions. •...
  • Page 16: Part 3: Specifications

    Part 3: Specifications...
  • Page 17: Service-Truck Model

    PART 3: SPECIFICATIONS 3.1 Alpha Mutt Service-Truck Model ® Specifications: Connection Type: 7-Way Round Pin Power Input: 12/24V DC 5mA – 21A Ammeter: Source Output: 20A @ 12/24V DC Max. Op. Pressure: 120 psi Air Input: 1/4" npt (120 psi max.)
  • Page 18 3.2 Military-Grade, Rugged Tablet (Available with RT Models) Specifications: Operating System: Android 7.1 Screen Size: 8.0" Display Resolution: WXGA (1280 x 800) Touch Screen: Wet-Touch/Glove-Touch Modes, Stylus Included Memory: 16GB (Internal) Micro SD (Up to 256GB) Connector: Pogo Pin (Wireless, Quick Charging) Bluetooth v.4.2 ®...
  • Page 19: Part 4: Initial Setup

    Part 4: Initial Setup...
  • Page 20: Battery/Power Supply Requirements

    Pins should be checked for corrosion on both the cable and tester sides. If corrosion is present, clean connectors using ’s patented CLR156 Terminal Cleaners. Then clean the connections using IPA 8035A ®...
  • Page 21: Truck-Box Installation (For -S Models Only)

    4.3 Truck-Box Installation (For -S Models Only) models with “S” in the part number feature a slide-out base design. They are all-in-on The Alpha MUTT ® trailer testers built onto a platform with both the End User and Upfitter in mind. They are easy to install, easy to operate, durable and weather protected, as well as easy to service.
  • Page 22: Installing 12V Dc/Battery Connection

    Fig. 4-3D Installing 12V DC/Battery Connection is designed to have a constant 12V DC power supply from the vehicle’s NOTE: The Alpha MUTT ® battery system. The tester already incorporates onboard fuse protection, so no additional fusing is required. This operation can be performed in two ways. The Primary method is to leave the tester attached to the base, utilizing the extended position.
  • Page 23: Part 5: General Controls And Operations

    Part 5: General Controls and Operations...
  • Page 24: Mechanical Functions

    ABS App (See App Section for more details). Auto Shutdown Feature If left inactive for a period of 20 minutes, the Alpha MUTT will enter a Sleep Mode and power down. ®...
  • Page 25 5.2 Control Panel A. Start/Air In Button Initiates Emergency-Side air and enables additional air operation functionality. PSI readings will not display until this button is pressed. B. Emergency-Side Exhaust Button Exhausts all air pressure in both the Emergency and Service sides. C.
  • Page 26 H. Custom Button Activates custom shortcut. Shortcuts can be set by holding button for three seconds. I. Mute Button Mute all alerts. J. Lower LCD Screen Shows voltage, amperage, ABS readings, circuit settings and system menus. K. Bluetooth Paired Indicator ®...
  • Page 27: Right Side Panel

    5.3 Right-Side Panel...
  • Page 28 For running cable tests and connecting directly to tractor. F. Serial Tag Product part number and serial number. G. Shop Air Input A bulk-head air input that is used to connect an air compressor to the Alpha MUTT for testing air ® brakes on a trailer.
  • Page 29: Lower Panel

    A. Emergency-Side Air Out For connecting the Emergency-Side Gladhand hose (red). B. 7-Way Round Pin Cable Out to Trailer For connecting 7-way round pin trailer to the Alpha MUTT to test electrical circuits. Should also ® be used during cable tests (See Part 8: Electrical/Lighting Testing).
  • Page 30: Remote Controls

    5.5 Remote Controls The included 12-button remote control is preprogrammed to the Alpha MUTT and should never lose its ® programming. If you suspect a remote has lost its programming, contact Technical Support at 888-786- 7899 or email tech247@ipatools.com. How to Program the 12-Button Remote 1.
  • Page 31: Tablet Controls

    You can extend battery life by limiting tablet performance. Access the tablets screen brightness, timeout, and other battery saving options through the Settings app. Bluetooth Connection (BLE) ® The tablet controls the Alpha MUTT through a Bluetooth connection. See Part 6 for more information ® ® on Bluetooth ®...
  • Page 32: How To Check For Software Updates

    While we ® ® try to always send out testers with the most up-to-date version of software, it is good practice to check for updates before you begin using the tester. To access any Alpha MUTT updates, please visit ® http://updates.ipatools.com and register an account.
  • Page 33: Part 6: Bluetooth

    Part 6: Bluetooth ®...
  • Page 34: Installing The Bluetooth

    PART 6: BLUETOOTH ® The tablet controls the Alpha MUTT through a ® Bluetooth connection; 4.0 or newer BLE (Bluetooth ® ® Low Energy) technology. This technology provides faster response times at longer distances. If the BLE connection is lost during operation, you can attempt to...
  • Page 35: Bluetooth Bluetooth

    Bluetooth must be ® reestablished. • Bluetooth connectivity should be established within IPA apps, not through the main settings of ® ® the tablet.
  • Page 36 Part 7: Operating the Alpha MUTT ®...
  • Page 37 PART 7: OPERATING THE ALPHA MUTT ® 7.1 Application Setup The Alpha MUTT app can be found on the Home screen of the tablet. Press the icon to launch ® the application. The application is designed to be intuitive and easy to use. Review the following pages for basic operation flow and further instructions.
  • Page 38 7.2 Menu Bar Screens Home Screen Testing Screen Notes Screen Optional Classic Views for Diagnostics - Swipe right to access Reports Screen Help Screen Settings Screen (Multiple) Inspection Creator Screen Sideswipe for alternate screens...
  • Page 39 7.3 Diagnostic Controls A. Stop/Reset Report Press once during diagnostics to stop report before completion. Press again to clear all diagnostics reported. B. Notes Press to log a note with report. Notes can be viewed on the Notes List page or on the report once completed.
  • Page 40 Part 8: Electrical and Lighting Testing...
  • Page 41 NOTE: Some advanced functions may not be listed on the face panel, so it’s important to read the manual in its entirety to ensure that you are getting the full use of this diagnostic system. 8.1 Pretest Checklist The pretesting checklist should always be completed prior to using the Alpha MUTT ® Tester Placement •...
  • Page 42 8.2 Selecting a Circuit Circuits can be selected for testing manually, with the remote control and tablet, or by initiating Auto Cycle mode. Manually 1. Turn the Circuit Control knob to select a circuit. The control knob is automatically set to Ground Integrity when power is turned on.
  • Page 43 Auto-Cycle Mode Auto Cycle mode automatically tests one circuit at a time in a clockwise rotation. Manually 1. Press and release the Circuit Control knob. The AUX 2 indicator should illuminate. 2. A five-second delay commences between circuit sections. 3. Circuits are automatically tested one at a time in a clockwise rotation.
  • Page 44 A sudden loss of ® ground while testing circuits will present as open circuits on each selected circuit. To confirm ground status, turn control knob back to the ground position. While in ground position, the Alpha MUTT ® continuingly monitors the ground status.
  • Page 45 8.4 Fault Indication Open Circuit An open circuit fault warning is triggered when the circuit draws under 4mA of power. The Alpha MUTT ® has a circuit detection resolution of 2mA. (A single LED with an LED bulb will draw 5-7mA of current.)
  • Page 46 8.5 Activating Hazard Lights The four-way flashers on the trailer can be activated manually, with the remote control or via the tablet. Manually 1. To activate/deactivate, access Hazard mode as a shortcut setting via the Shortcut button, or via the function menu which is located as a submenu in the main system settings.
  • Page 47 8.6 All Circuits On (Override) Mode All Circuits On mode will engage all electrical circuits at the same time. While short circuit sensing is operational in this mode, if a short circuit is found, the Alpha MUTT will not be able to identify which ®...
  • Page 48 Part 9: Air Brake Testing...
  • Page 49 1. Push the Power Source switch to the ON position. directly to your trailer’s air system, securing the red 2. Attach gladhand hoses from the Alpha MUTT ® hose to the Emergency Side and the blue hose to the Service Side.
  • Page 50 This feature allows you to see the slacker adjustments and the pushrod travel in real time. Brakes can be activated manually, with the remote control or via the tablet. NOTE: The Alpha MUTT is equipped with a safety feature which requires the user to acknowledge ®...
  • Page 51 2. Press the Start/Air In button on the Emergency side to engage air testing. a. Follow safety prompts and remember to chock trailer wheels prior to testing. 3. Point the remote in the general direction of the Alpha MUTT ®...
  • Page 52 WARNING: DO NOT connect shop air until completing the testing set-up procedure. Failure to fully understand these warnings can result in minor to serious injury and possibly death. NOTE: The Alpha MUTT is equipped with a safety feature which requires the user to acknowledge ®...
  • Page 53 Automatic Leak Down Test An Automatic (AUTO) Leak Down test allows a technician/operator to perform a test with preset pass/fail parameters (time and acceptable psi loss). The Alpha MUTT will conduct the Leak Down test and display ® results when complete. For testers that include the IPA tablet, these results are recorded as a data point ®...
  • Page 54 Part 10: Diagnostics...
  • Page 55 The Alpha MUTT is equipped with integrated ABS diagnostics and allows for the ability to access and ® clear ABS fault codes. The Alpha MUTT allows a technician to access ABS diagnostics via the control ® panel LCD screen or software app on the tablet.
  • Page 56 NOTE: Turning the control knob clockwise allows you to scroll through each sub menu. Turning the control knob counterclockwise will back you out one sub menu at a time. communicates with the trailer’s ABS ECU in real time, via IPA ’s proprietary internal The Alpha MUTT ®...
  • Page 57 Accessing Active Faults (Sub Menu #1) With the ACTIVE FAULTS Sub Menu 1 selected and the Active SID and FMI codes displayed, turn the control knob clockwise to cycle through the fault codes (Fig. 1-A). Press the control knob (Fig. 1- B) to read the Fault Description (Fig.
  • Page 58 The application is designed to be intuitive and easy to use. Review the ABS application overview below for basic operation flow and further instructions. For technical assistance, please call 888-786-7899. NOTE: The ABS Application provided with the Alpha MUTT was launched in 2019. IPA will update ®...
  • Page 59 10.4 Failure Mode Identifier (FMI) Assignments The Failure Mode Identifier, FMI, describes the type of failure detected in the subsystem identified by the PID or SID. The FMI and either the PID or SID combine to form a given diagnostic code (see PID 194 for added clarification).
  • Page 60 10.5 SAE J1587 MID 137 SID List Brake SIDs (MIDs = 136, 137, 138, 139, 246, 247) Reserved Wheel Sensor ABS Axle 1 Left Wheel Sensor ABS Axle 1 Right Wheel Sensor ABS Axle 2 Left Wheel Sensor ABS Axle 2 Right Wheel Sensor ABS Axle 3 Left Wheel Sensor ABS Axle 3 Right Pressure Modulation Valve ABS Axle 1 Left...
  • Page 61 Electronic Pressure Control, Axle 1 Pneumatic Back-up Pressure Control, Axle 1 Brake Pressure Sensing, Axle 1 Electronic Pressure Control, Axle 2 Pneumatic Back-up Pressure Control, Axle 2 Brake Pressure Sensing, Axle 2 Electronic Pressure Control, Axle 3 Pneumatic Back-up Pressure Control, Axle 3 Brake Pressure Sensing, Axle 3 Electronic Pressure Control, Trailer Control Pneumatic Back-up Pressure Control, Trailer Control...
  • Page 62 Part 11: Inspections and Reporting...
  • Page 63 PART 11: INSPECTIONS AND REPORTING The Alpha MUTT app performs wireless diagnostic electrical tests and PM inspections. It includes an ® Inspection Creation feature which allows users to create custom DOT and PM inspections and generates, stores and shares reports via email. Sharing reports requires an email account be set up on the tablet.
  • Page 64 Pass Result 1. If all circuits pass inspection, the app will prompt you to perform a walk-around, visual inspection. 2. Select ALL CIRCUITS ON. Walk around the vehicle to visually ensure all bulbs/lamps are illuminated. 3. Once confirmed, press the PASS switch next to the darkened SUBMIT REPORT button.
  • Page 65 Fail Result 1. If some or all circuits fail, the app will prompt you to troubleshoot or finalize the inspection. Once a FAILED result is found, you have four options to proceed: 2. A: Troubleshoot the failed circuits. B: Save the inspection and test again. C: Save and test a new trailer.
  • Page 66 11.2 DOT/PM Inspections 1. To begin, select DOT/PM INSPECTIONS from the main menu. Make sure there is Bluetooth ® connectivity between the tablet and the Alpha MUTT ® 2. Turn the desired Test Methods on or off with each toggle switch. Custom Inspections that are created in the Inspection Create tab will be visible only if they are set as DEFAULT in the Inspection Creator section of the app.
  • Page 67 Truck Inspections Controls A. Inspection Categories Standard DOT/PM Inspection categories. Editable in Inspection Creation Tab. B. Inspection Results Standard DOT/PM Inspection-result categories. Press anywhere in box to toggle on/off. C. Comments Comments can be added per line by pressing ADD COMMENT and entering desired text in the pop-up window.
  • Page 68 Trailer Inspections Controls A. Inspection Categories Standard DOT/PM Inspection categories. Editable in Inspection Creation Tab. B. Inspection Results Standard DOT/PM Inspection-result categories. Press anywhere in box to toggle on/off. C. Comments Comments can be added per line by pressing ADD COMMENT and entering desired text in the pop-up window.
  • Page 69 11.3 Saved Reports 1. Reports generated through the Alpha MUTT ® can be found in the Reports tab on the left side of the screen. 2. To toggle between Electrical and Inspection Reports, press the button in the bottom right corner.
  • Page 70 11.4 Inspection Creator Tab The Alpha MUTT app allows users to create custom inspections using default templates and select ® which inspections will appear when initializing an inspection. 1. To begin, select the INSPECTION CREATOR tab from the left side menu.
  • Page 71 11.5 Sample Reports Alpha MUTT with ABS Diagnostic Report ® (Software Field Title Inserted Info from app allows for user App Version: Version: 1.2.63 uploaded logos) Report Created: 4/1//2020 Company Name: Time Stamp: 03:08:48 PM Address 234 Tinker Street User Id:...
  • Page 72 VEHICLE HISTORY RECORD UNIT #: REPAIR ORDER # VEHICLE TYPE: Trailer MOTOR CARRIER OPERATOR NAME: Innovative Products of America STREET: 234 Tinker St CITY, STATE/PROVINCE, ZIP CODE: Woodstock, N.Y., 12498 LICENSE PLATE NUMBER/STATE: 3456JK LOCATION: Woodstock VIN: XXXXXX HUB READING: HOURS: OWNER OF VEHICLE: QUALIFIED INSPECTORS NAME:...
  • Page 73 6. Safe Loading A. Part(S) of vehicle or conditions of loading such that the spare ✔ tire or any part of the load damage can fall onto the roadway. ✔ B. Protection against shifting cargo. ✔ C. Container securement devices on intermodal equipment. 7.
  • Page 74 VEHICLE HISTORY RECORD UNIT #: REPAIR ORDER # VEHICLE TYPE: Trailer MOTOR CARRIER OPERATOR NAME: Innovative Products of America STREET: 234 Tinker St CITY, STATE/PROVINCE, ZIP CODE: Woodstock, N.Y., 12498 LICENSE PLATE NUMBER/STATE: 3456 LOCATION: Woodstock VIN: XXXXXX HUB READING: HOURS: OWNER OF VEHICLE: QUALIFIED INSPECTORS NAME:...
  • Page 75 10. Brakes A. Air Leaks, Valve Operation ✔ B. Missing/Loose Components ✔ C. Lubricate Cams & Slack Adjuster Zerks ✔ D. Adjust Brakes. 1 1/2" Max Travel ✔ E. Inspect Brake Chamber ✔ F. Inspect Hoses, Leaks/Cracks/Swelling ✔ 11. Brakes Pad Thickness Min 1/4" ✔...
  • Page 76 Part 12: Updating Firmware...
  • Page 77 Rotate the knob clockwise until you reach the PLC FIRMWARE menu option. Press the control knob and allow the unit to read the newly installed firmware revision. NOTE: For assistance or questions regarding updating the firmware on the Alpha MUTT please ®...
  • Page 78 Part 13: Maintenance...
  • Page 79 This will ensure a proper connection when using your Alpha MUTT ® • Do not allow water to enter the control panel. • Store in a cool, dry area when not in use and cover your Alpha MUTT to prevent dust from ®...
  • Page 80 RGA # will be assigned along with next step instructions for the customer. NOTE: • Always take at least 5 pictures of your tester BEFORE sending the tester to the IPA facility. ®...
  • Page 81 Acquire RGA If In-Warranty If Out-of-Warranty If In-Warranty If Out-of-Warranty Parts Sent to Parts Sent to Send Tester to Send Tester to Customer – IPA Customer After Facility – IPA Facility – ® ® ® ® Covers Shipping Payment is...
  • Page 82 Part 14: Troubleshooting...
  • Page 83 - The Alpha MUTT does not house any internal memory for saving reports. All memory is ® stored on the Tablet. Tablets do feature expandable storage options. Call IPA Tech ® Support for further information on how to expand memory.
  • Page 84 • The ABS computer can be heard powering up when the ABS circuit is selected, but no codes are retrieved. The ABS light is on, signaling there is an Active Fault but the Alpha MUTT detects no ® communication from the ABS ECU on the trailer.
  • Page 85 14.3 Common Troubleshooting Solutions Symptom Possible Cause Solution Remove wires going to cig. Shorted cig. socket or power 30-Amp fuse keeps blowing. socket. If fuse still blows, call connector. Tech Support at 888-786-7899. Main Bluetooth turned off on Ensure Bluetooth is turned on ®...
  • Page 86 Part 15: Exploded Views and Diagrams...
  • Page 87 PART 15: EXPLODED VIEWS AND DIAGRAMS This Page Left Blank on Purpose 15-1...
  • Page 88 15-2...
  • Page 89 15.1 Body Exploded View ITEM PART # DESCRIPTION FAS-0150 10-32 X 3/8 PHILLIPS 005600-3R 5600 TOP 5600-DRAWER-AS 5600 DRAWER 005600-11R 5600 DRAWER PANEL 005600-2R 5600 BACK 5600-FACE-AS 5600 FACE ASSEMBLY 5600-DOOR-AS 5600 DOOR ASSEMBLY FAS-0036 ¼-20 X 3/8 HEX CAP 5600-BUMPER DOOR BUMPER FAS-0161...
  • Page 90 15-4...
  • Page 91 15.2 Face Exploded View ITEM PART # DESCRIPTION 007900K-57 4-40 HEX NUT PCB0022-AS2 DIGITAL AIR PCB PCB0021-AS2 CONTROL BOARD LCD STANDOFF SW0002B LONG ENCODER COLLAR 007900K-11B COLLAR O RING NYLON BOARD STANDOFF NYLON WASHER DUAL LINE LCD 005600-1R 5600 FACE PUSH BUTTON PCB 7900K-32A 6-32 X 3/8 PHILLIPS...
  • Page 92 15-6...
  • Page 93 15.3 Side-Panel Exploded View ITEM PART # DESCRIPTION FAS-0144 10-32 THIN NYLON LOCKNUT RLY16 POWER RELAY 7900K-57 4-40 NUT 7900K-59 #4 SPLIT LOCK WASHER 7900AP-7 #4 FLAT WASHER BUZ-AS2 PIEZO FAS-0007 5/16-18 NUT FAS-0008 5/16 LOCK WASHER FAS-0006 5/16 FLAT WASHER 3’...
  • Page 94 15-8...
  • Page 95 15.4 Storage Drawer Exploded View ITEM PART # DESCRIPTION VEL-0004 VELCRO STIP 5700A-PLCPLT-AS PLC ENCLOSURE ASSEMBLY 7900K-57 4-40 HEX NUT 7900K-59 #4 LOCK WASHER MUT-SOLF-AS SOLENOID F AS. MUT-SOLG-AS SOLENOID G AS. 005600-8R DRAWER TOP 005600-CHAINBRK 2PC BRACKET SET 005600-CHAIN ECHAIN 24 LINKS FAS-0144 10-32 NYON LOCKNUT...
  • Page 96 15-10...
  • Page 97 15.5 Door Exploded View ITEM PART # DESCRIPTION 005600-5R 5600 DOOR FAS-0144 10-32 NYLON LOCK NUT 5600-DOORPNL-AS 5600 AL DOOR PANEL ½” FENDER WASHER FAS-0157 7862-3MIL DOORKNOB FAS-0059 #10 FLAT WASHER 005600-15 RUBBER DOOR STRAP ¼” FALT WASHER FAS-0170 FAS-0050 10-32 SHAOULDER SCREW FAS-0169 10-24 EYE BOLT &...
  • Page 98 15-12...
  • Page 99 15.6 Slide-Out Base Exploded View ITEM PART # DESCRIPTION ¼-20 X 1-1/2” FLAT HEAD FAS-0140 16” UNIT SLIDE PAIR 005600-SLIDE2 10-32 X ½” FLAT HEAD HEX SOCKET FAS-0143 ¼-20 X 5/8” FLAT HEAD HEX SOCKET FAS-0146 ALU00016-MIL ANGLE BRACKET FAS-0145 #10 WASHER SS FAS-0144 10-32 NYLON LOCK NUT...

Table of Contents