Atex Certification - Delta DE212 GLOBAL Operation And Installation Manual

Wireless deadman system with differential pressure switch function for aero plane refuelling trucks and dispensers
Table of Contents

Advertisement

2.4
EX CERTIFICATION.
The handheld unit, the TX212 transmitter is Ex approved, to verify this, look at the identification label
located under the handle.
Note that the certification is no longer valid if the TX212 is repaired by an un-authorized workshop, or
if the instruction given in this document is not followed.
The Ex-standards applied for this certifications are:
For the EU: II 2 G Ex ib IIC T4, EN 60079-0:2012 + A11:2013 and EN 60079-11:2012
IECEx: IEC 60079-0 Ed.6 and IEC 60079-11:2011
ATEX certification number: ZELM 03 ATEX 0139X
IECEs certification: IECEx ZLM 13.005X
The label tells the name of the producer and that the unit has an ATEX and IECEx certification, and is
allowed to be used in Ex environment, Zone 1.
The ART:
is the article number of the product
The TYPE:
is TX212-2S, given that it is a transmitter of the DE212 system.
2S says that it has two functions and STOP.
The S/N:
is the serial number of the unit, which is a unique number.
The DATE:
gives the production date.
The PROG:
gives the software version of the transmitter.
The FREQ:
gives the radio frequency of the transmitter.
The VOLT:
gives the nominal battery voltage.
The IP:
gives the protection grade of the transmitter
D
RC AS
ELTA
User and Installation Manual, DE212 GLOBAL
Page 9 of 36
Document 02743

Advertisement