E X Certification - Delta DE212-2S GLOBAL DSD Operation And Installation Manual

Wireless deadman system
Table of Contents

Advertisement

1.6
E
C
X
ERTIFICATION
The handheld unit, the TX212 transmitter is Ex approved, to verify this, look at the identification label
located under the handle.
Note that the certification is no longer valid if the TX212 is repaired by an un-authorized workshop, or
if the instruction given in this document is not followed.
The Ex-standards applied for this certifications are:
IECEx: IEC 60079-0 Ed.5 and IEC 60079-11 Ed. 5
IECEs certification: IECEx ZLM 13.0005X
The label tells the name of the producer and that the unit has an ATEX and IECEx certification, and is
allowed to be used in Ex environment, Zone 1.
The ART:
is the article number of the product
The TYPE:
is TX212-2S, given that it is a transmitter of the DE212 system.
2S says that it has two functions and STOP.
The S/N:
is the serial number of the unit, which is a unique number.
The DATE:
gives the production date.
The PROG:
gives the software version of the transmitter.
The FREQ:
gives the radio frequency of the transmitter.
The VOLT:
gives the nominal battery voltage.
The IP:
gives the protection grade of the transmitter
TX212-2S RT identification label:
D
RC AS
ELTA
.
User and Installation Manual, DE212-2S DSD
Page 9 of 24
Document 02481

Advertisement

Table of Contents
loading

This manual is also suitable for:

02910