For special applications, the control unit has inputs for connection of wired deadman override and external STOP. The DE212 system is based on the latest technology and has the flexibility to meet new operational demands by upgrading the software in the control unit.
Installation Manual for CU220 DP 2. I NSTALLATION NTRODUCTION The CU212 DP control unit is designed to monitor the DP Gauge modified by a switch or a sensor. The control unit is available in two versions: Art.no. 02358, prepared for reading of a DP reed switch NO or NC. b) Art.no.
Installation Manual for CU220 DP ONNECTIONS CU212 DP REED SWITCH ONNECTIONS Valid for Art.no 02358, and SW/Program 02335. Only DP reed switch input, ON/OFF type. The power supply can be 12 or 24VDC. See figure below. Control unit board Connector P1 Connector P3 Timer Beeper output Timer Warning light output...
Installation Manual for CU220 DP CU212 DP C ONNECTIONS Valid for Art.no 02865, and SW/Program 02864. For Reed switch or Namur sensor NG500A, Ex certified. The power supply can be 12 or 24VDC. See figure below. º Control unit board Connector P1 Connector P3 1.
Installation Manual for CU220 DP P3-2. DIFFERENTIAL PRESSURE INPUT This function is added in order to prevent refuelling after a high DP signal is detected. The input signal can be generated by a ON-OFF switch or a Namur inductive proximity sensor. On CU220 art.no.
Installation Manual for CU220 DP ECHNICAL This equipment is designed for failsafe operation, meeting the stringent requirements for safe operation. It is in accordance to EU’s demands to CE-label the equipment. ENERAL PECIFICATION * Temperature Range: Operational and storage: -25 to +65º C. * Shock Resistance: 2 m free-fall on concrete floor.
The guaranty ceases 12 months after the delivery date. Delta RC AS AS or appointed repair workshop, is bound to repair and replace defect parts in its products, free of charge, in its main workshop during its normal working hours. Packages being sent to and from Delta RC AS are in the responsibility of the purchaser, as he is also economically responsible for paying the transportation charges, toll, insurance and other related charges.
Any other defect or missing part during this period is not covered by the warranty. Should Delta RC AS offer a service unit during the warranty time, the purchaser pays for the transportation, insurance and a weekly rent.
Page 12