Delta DE212 GLOBAL Operation And Installation Manual page 6

Wireless deadman system with differential pressure switch function for aero plane refuelling trucks and dispensers
Table of Contents

Advertisement

Connector
Functional description
P1 in receiver
1
Timer beeper output
2
Timer warning output
3
Extra function, for
hose reel or pump speed control
4
5
Normally closed=activated output, opens
when STOP is pressed
6
Interlock (transmitter is charging)
Output is active when transmitter is
7
Minus-pole for input voltage
8
Plus-pole for input voltage
9
10
DP Reset / Override
Receiver connections and functional selection.
Note: All outputs are 12 or 24V, same as the power supply voltage, when activated.
D
RC AS
ELTA
Deadman output
charging
Do not connect
User and Installation Manual, DE212 GLOBAL
Receiver function
Select, SW2
SW2-1: 2 min. timer ON/OFF
ON= timer active, OFF=No timer
SW2-2: Extra function.
Simultaneous or no simultaneous operation with the
Deadman function.
ON = Simultaneous operation
SW2-4: DP Enable
Page 6 of 36