Receiver connections, connector P3:
Functions installed with receiver software program: 02046
Conn.
Functional description
P3
External override
1
The Deadman function is active as long as this input is
low, connected to GND
2
Not in use, for future expansion.
External STOP.
3
Stops all functions in the receiver when connected to GND
4
Not in use, for future expansion.
GND, ground or common terminal.
5
Same as P1, term. 7
NOTES:
•
Input voltage is 11 to 35 V DC. All outputs give input voltage when activated.
•
NOTE: Input voltage above 35V, will shut down the receiver.
•
Note that the potential between the minus pole and ground, must not be greater than 50VDC/AC peak.
•
The timer warning output operates as follows: when the Deadman function is activated, the time warning
output also go active, supplying 12/24V out. When 30 seconds are left of the 2 min. time period, the
standard period, the output change from a steady output, to an off/on signal during the last 30 seconds of
the time period. The output is intended for connection to an indicating lamp, visible for the operator. The
on/off flashing lamp is intended to warn the operator to restart the time period.
•
The timer beeper output is active only as long as the warning signal is flashing.
If external connection box is delivered, the connections are as follow:
Cable
Receiver
connector
marking
YE-GN
6
6
5
5
4
4
3
3
2
2
1
1
7
7
8
8
D
RC AS
ELTA
Not in use
Interlock
STOP
Deadman output
Extra function
Timer warning
Timer beeper
Minus-pole, input voltage
Plus-pole, input voltage, 12/24VDC
User and Installation Manual, DE212 GLOBAL
SW2-3 : External override
ON= Ext. override active. OFF=Ext.
override disabled
Do not connect
This function is always enabled
Do not connect
Function
Page 7 of 36