3.12.6 Pulley assembly
Heat both inner rings of the bearings (5) simultaneously up to 120 °C.
Pay the utmost attention when heating the bearings (5) because they have a rubber shield.
Place the bearing (5), spacer (6), bearing (5) and Seeger ring (4) on the eccentric (3).
Position the Seeger ring (1) on the eccentric (3).
Moster 185 Plus - Maintenance manual - V1
102