Quick Parameter Reference
QUICK PARAMETER REFERENCE
0
Modbus
Parameter/
Address
001
Firmware Version
010
Rotating Switch S1
011
Rotating Switch S2
012
Rotating Switch S3
015
Status of the Digital Inputs
016
Status of the Digital Outputs
020
RS485 - Address
RS485 - Baud Rate
021
022
RS485 - Byte Configuration
100
RS485 - Time for Communication
Fault
101
RS485 - Action for Communication
Fault
120
P1 Contactor 1 Closing Time
121
P1 Contactor 1 Opening Time
122
P1 Contactor 2 Closing Time
123
P1 Contactor 2 Opening Time
124
P2 Contactor 1 Closing Time
P2 Contactor 1 Opening Time
125
126
P2 Contactor 2 Closing Time
127
P2 Contactor 2 Opening Time
128
P3 Contactor 1 Closing Time
129
P3 Contactor 1 Opening Time
130
P3 Contactor 2 Closing Time
P3 Contactor 2 Opening Time
131
132
P4 Contactor 1 Closing Time
133
P4 Contactor 1 Opening Time
134
P4 Contactor 2 Closing Time
135
P4 Contactor 2 Opening Time
150
P1 C1 Operation Counter
P1 C2 Operation Counter
151
152
P2 C1 Operation Counter
153
P2 C2 Operation Counter
154
P3 C1 Operation Counter
155
P3 C2 Operation Counter
156
P4 C1 Operation Counter
P4 C2 Operation Counter
157
158
Save Operation Counters in the mem NV false to true
4 | SCW100
Description
0.0 to 655.35
0 to 15
0 to 15
0 to 15
Bit 0 = DI1
Bit 1 = DI2
Bit 2 = DI3
Bit 3 = DI4
Bit 4 = DI5
Bit 5 = DI6
Bit 6 = DI7
Bit 7 = DI8
Bit 8 = DI9
Bit 9 = DI10
Bit 10 = DI11
Bit 11 = DI12
Bit 0 = DO1
Bit 1 = DO2
Bit 2 = DO3
Bit 3 = DO4
Bit 4 = DO5
Bit 5 = DO6
Bit 6 = DO7
Bit 7 = DO8
0 to 255
0 = 9600 kbps
1 = 19200 kbps
2 = 38400 kpbs
3 = 57600 kbps
4 = 76800 kpbs
0 = no parity, 2sb
1 = even parity, 1sb
2 = odd parity, 1 sb
0.0 to 6553.5 s
0 = No Action
1 = Turn off Outputs
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535 ms
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
Factory
Adjustable Range
Setting
0.0 s
1
false
User
Properties
Setting
-
ro, 16 bit
-
ro, 8 bit
-
ro, 8 bit
-
ro, 8 bit
-
ro, 12 bit
-
ro, 8 bit
-
ro, 8 bit
-
ro, enum
-
ro, enum
rw, 16 bit
rw, enum
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
-
ro, 16 bit
rw, bool
Page
5-1
5-1
5-1
5-1
5-2
5-2
5-3
5-3
5-3
5-3
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-4
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-5
5-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scw100-sm

Table of Contents