Connecting

7.1

Safety notes for connection

If auxiliary power is required, check that it corresponds with that on the nameplate and with
the test certification valid for your country.
7.2

Electrical connection of the power supply

Procedure
Note
Appliance plug
You can use any appliance plug that fulfills the conditions of DIN EN 60320-1, ≥6 A.
The mains supply line must comply with the valid regulations and conditions for the place of
installation and be provided with a protective conductor at the potential of the housing. The
cross-section of each wire has to be ≥ 1 mm
in the connector at the position marked.
● Ensure that a mains disconnection device is located in the direct vicinity of the device (for
● Ensure that the supply voltage present matches that which is specified on the nameplate
Rack-mounted device
Operating Instructions, 01/2013, A5E31874006-01
WARNING
load rating, see nameplate).
of the device.
. The phased terminal lead must be connected
2
7
39