7

Envelope Monitoring

PME100 is configured for Machine Envelope Control (MEC) only. MEC will
warn and prevent equipment motion. MEC is achieved by interacting with the
machine's hydraulics. This allows motion to be cut to any section of equipment
that has reached a restriction but allow other sections to operate
unhindered unless they too reach the set restriction.
When setting a limit, either by entering a known value or by positioning the machine at
the desired limit, make sure any implement attached is in its least favourable position as
the system is unaware of any implement fitted unless listed in Tool Selection, see section
6.1.
PME100 monitors the highest part of the machine, but may be unaware of any
implement fitted therefore make sure any implement attached is in its least favourable
position.
Height Limiting
MEC
OFF: when operating with an inactive limit the indicator will have a cross painted
on it.
ON: when operating with an active limit the indicator will not have a painted on
cross on it.
Care should be taken to test that the limit or limits are set correctly.
that the limit activates at the set point. A limit cannot be deactivated when
close to or at the limit. Observe the operational limitations given in section 4.
562100-000, Issue1.1, December 2015
Once a limit is set, the internal alarm will sound and the RED LED
will light if the equipment reaches the current limit. Always check
Exit to previous screen