Operating and Hazard Situation Recommendations
Operating Recommendations
When using envelope monitoring:
When setting a slew restriction, make sure any implement attached is in its least fa-
vourable position
Check for correct operation once the restriction or restrictions have been set
Reduce operating speed
Reset slew restriction if the machine
Do not move the equipment quickly when close to a restriction
Do not operate the machine in a reckless manor
Do not travel with a restriction set
Reset the slew restriction if the machine is relocated
Hazard Situation Recommendations
In a limit hazard state:
Return the control levers to neutral once a limit has been reached if appropriate
Operate the machine at a slow speed
Do not travel

4.1 MEC Override

The system can optionally be fitted with a master override key switch. Turning
the key to the override position will allow normal operation of the hydraulic
services regardless of safety status. When the system is in override, the ex-
ternal alarm (if fitted) will be active, and the beacon (if fitted) will be off, the
red LED will flash and an 'In Override' message will appear on the display in-
dicating that the machine is overridden. The override state will automatically
return to normal operating mode after 30 minutes (default value), regardless
of the system status. The master override key switch must be cycled to put
the system back into override.The master override key switch should only be used if the
safety system is not operational due to a fault and the machine needs to be moved due to
its location presenting a hazard. The override status is recorded in the system data log.
To access the override key switch, the seal may need to be broken.