ENGLISH

TROUBLES AND TROUBLESHOOTING

Problem
The ON indicator doesn't light
up (12), no mist release.
The indicator (12) is glowing
red, no mist release.
Mist smells unpleasantly.
Low mist release intensity
Foreign noise during the air
humidifier operation
Notes:
Non-observance of the rules for cleaning the
"sprayer" from mineral deposits affects the air
humidifier performance. In this case clean the
"sprayer".
If the tap water used is hard, use household fil-
ters for additional water cleaning or mix it with
distilled water in proportion 1:1.

DELIVERY SET

Air humidifier – 1 pc.
Removable lid with nozzle – 1 pc.
Removable water tank – 1 pc.
Remote control – 1 pc.
Instruction manual – 1 pc.
Warranty certificate – 1 pc.

TECHNICAL SPECIFICATIONS

Power supply: 100-240 V ~ 50 Hz
Rated input power: 20 W
Water tank capacity: 2.5 L
Water flow: up to 220 ml/h
Humidified area: up to 20 m
The manufacturer preserves the right to change
design, structure and specifications not affect-
ing general principles of the unit opera-
tion without a preliminary notification due to
which insignificant differences between the
manual and product may be observed. If the
Possible causes
No supply voltage.
Water tank is empty. Fill the water tank with water.
First use of the unit.
Dirty or stale water.
Sprayer is dirty.
The unit is placed
on an uneven or
unstable surface.
2
6
Troubleshooting
Connect the unit to the mains.
Plug another, known good appliance to the
socket to make sure that the socket works
properly.
Pour out the water and leave the tank open
for 12 hours in a cool darkened place
Unplug the unit, remove the water tank,
pour out the water, wash the tank and fill it
with clean boiled or distilled water.
Unplug the unit and clean the sprayer.
Unplug the unit and level the unit body or
move the air humidifier to another place.
user reveals such differences, please report
them via e-mail info@vitek.ru for receipt of an
updated manual.
RECYCLING
For environment protection do not throw out the
unit and the batteries (if included), do not discard
the unit and the batteries with usual household
waste after the service life expiration; apply to
specialized centers for further recycling.
The waste generated during the disposal of the
unit is subject to mandatory collection and con-
sequent disposal in the prescribed manner.
For further information about recycling of this
product apply to a local municipal administration,
a disposal service or to the shop where you pur-
chased this product.
Unit operating life is 3 years
Guarantee
Details regarding guarantee conditions can be
obtained from the dealer from whom the appliance
was purchased. The bill of sale or receipt must be
produced when making any claim under the terms
of this guarantee.