Installation Position A10Fzg, A10Vzg; Below-Reservoir Installation (Standard) - Bosch Rexroth 10 Series Instruction Manual

Axial piston units
Table of Contents

Advertisement

38/72
A10FZO, A10VZO, A10FZG and A10VZG series 10 | Installation
Bosch Rexroth AG, RE 91485-01-B/2021-11-18
6
F
h
L
ES min
L
S
1
h
s max
h
SB
t min
h
min
Abb� 18: Above-reservoir installation A10VZO with installation position 6–8
Tabelle 20: Above-reservoir installation
Installation position
6 (drive shaft horizontal)
7 (drive shaft vertically up)
8 (drive shaft vertically down)
L, L
Drain port
1
F
Filling/air bleeding
S (A/B) Suction port
h
Minimum required immersion depth
t min
(200 mm)
h
Minimum required distance to
min
reservoir bottom (100 mm)
7�4 Installation position A10FZG, A10VZG
The following installation positions are permissible. The pipeline routing shown
illustrates the basic layout.
7�4�1 Below-reservoir installation (standard)
Below-reservoir installation means that the axial piston unit is installed outside of
the reservoir below the minimum fluid level.
Recommended installation position: 1.
Because complete air bleeding and filling is not possible in installation
positions 2 and 3, the axial piston unit must be air bled and filled in
a horizontal position prior to installation.
7
F
h
L
ES min
1
L
h
S
s max
h
SB
t min
h
min
Air bleed
F
F
F
h
Minimum height required to prevent
ES min
axial piston unit from draining
(25 mm)
h
Maximum permissible suction height
S max
(800 mm)
SB
Baffle (baffle plate)
8
F
h
S
ES min
L
L
h
1
h
SB
t min
h
min
Filling
L
L
1
L
s max

Advertisement

Table of Contents
loading