Tabelle 17: Inside-reservoir installation
Installation position
4 (drive shaft horizontal)
5 (drive shaft vertically up)
4
L
SB
L
1
S
Abb� 16: Inside-reservoir installation A10VZO with installation position 4–5
Tabelle 18: Inside-reservoir installation
Installation position
4 (drive shaft horizontal)
5 (drive shaft vertically up)
L, L
Drain port
1
F
Filling/air bleeding
S (A/B) Suction port
h
Minimum required immersion depth
t min
(200 mm)
7�3�3 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.
Observe the maximum permissible suction height h
The permissible suction height h
Air bleed
Via the highest
available port L
Via the highest
available port
L (NG3 to 18)
L
(NG21 to 63)
1
5
L
1
L
SB
S
Air bleed
Via the highest
available port L
Via the highest
available port L
1
h
Minimum required distance to
min
reservoir bottom (100 mm)
SB
Baffle (baffle plate)
is derived from the total pressure loss.
S
Filling
Automatically via the open
port L, by position below
hydraulic fluid level
Automatically via the open
port L or L
due to the
1
position under the hydraulic
fluid level
Filling
Automatically via the open
port L or L
due to the
1
position under the hydraulic
fluid level
Automatically via the open
port L or L
due to the
1
position under the hydraulic
fluid level
= 800 mm.
S max

Advertisement

Table of Contents
loading

Table of Contents