Installation
Ground The
The System
System
Ground
Ground
The
System
The equipment must be grounded to reduce the
risk of static sparking. Static sparking can cause
fumes to ignite or explode. Grounding provides an
escape wire for the electrical current.
• Always
Always ground the entire fluid system as
Always
described below.
• The pumps are not
used to pump flammable fluids must be properly
grounded.
• Follow your local fire codes.
Before operating the pump, ground the system as
explained below.
Pump: Always
Always ground the entire fluid system by
• Pump:
Pump:
Always
making sure the fluid has an electrical path to a
true earth ground.
Air and
and fluid
fluid hoses:
hoses: Use only flexible grounded
• Air
Air
and
fluid
hoses:
hoses with a maximum of 500 ft (150 m) combined
hose length to ensure grounding continuity.
• Air
Air compressor:
Air
compressor: Follow manufacturer's
compressor:
recommendations.
Fluid supply
supply container:
container: Follow local code.
• Fluid
Fluid
supply
container:
Solvent pails
pails used
used when
• Solvent
Solvent
pails
used
code. Use only conductive metal pails, placed
on a grounded surface. Do not place the pail
on a nonconductive surface, such as paper or
cardboard, which interrupts grounding continuity.
Check your system electrical continuity after the
initial installation, and then set up a regular schedule
for checking continuity to be sure proper grounding
is maintained.
10
Tel: 866-777-6060
Fax: 866-777-6383
not conductive. Any system
not
when flushing:
flushing: Follow local
when
flushing:
Springer Pumps, LLC
Air

Air Lines

Air
Lines
Lines
1. Install an air regulator and gauge (C) to control
the fluid pressure. The fluid stall pressure will be
the same as the setting of the air regulator.
2. Locate a bleed-type master air valve (B) close to
the pump and use it to relieve trapped air. Be
sure the valve is easily accessible from the pump
and located downstream from the regulator.
Trapped air can cause the pump to cycle
unexpectedly, which could result in serious
injury from splashing.
3. Locate another master air valve (D) upstream
from all air line accessories and use it to isolate
them during cleaning and repair.
4. An air line filter (C) removes harmful dirt and
moisture from the compressed air supply.
5. Install a grounded, flexible air hose (A) between
the accessories and the 1/4 npt(f) or 1/4 bspt
pump air inlet. Use a hose with a minimum 1/4 in.
ID. If a hose longer than 10 ft (3 m) is required,
use a larger diameter hose.
Website: www.springerpumps.com
334796G
Int'l: +001 267 404 2910