Battery Charging Profile Chart; Errors & Troubleshooting - Dometic Go Power! DURALITE 100 User Manual

Solar controller
Table of Contents

Advertisement

ITEM
Over Voltage Disconnect Voltage
Charging Limit Voltage
Over Voltage Reconnect Voltage
Equalize Charging Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect Charging Voltage
Low Voltage Reconnect Voltage
Under Voltage Warning
Reconnect Voltage
Under Voltage Warning Voltage
Low Voltage Disconnect Voltage
Discharging Limit Voltage
Equalize Duration
Boost Duration
1.
When the battery type is sealed, gel, flooded, the adjusting range of equalizing duration is 0 to180min and boost duration is
10 to180min.
2.
When setting a lithium battery type, (for example: a LiFePO4) use these rules when setting voltage parameters.
Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥
Float Charging Voltage > Boost Reconnect Charging Voltage.
Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharging Limit Voltage.
Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
Note
LFP1 is used for 12V Lithium batteries. LFP2 is used for 24V lithium batteries and should not be used for the DuraLite kit.
6. ERRORS AND TROUBLESHOOTING
No Power to LCD Screen
Solution 1
Check the connection between the DuraLite Kit and the controller, and the controller and the battery. The controller requires a mini-
mum voltage of 8v to run.
Solution 2
Your battery may be too far discharged to accommodate the controller. Keep the solar kit plugged in and placed in full sun for a few
hours and try the controller again.
[page 10] | gpelectric.com
SEALED
GEL
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
14.6V
——
14.4V
14.2V
13.8V
13.8V
13.2V
13.2V
12.6V
12.6V
12.2V
12.2V
12.0V
12.0V
11.1V
11.1V
10.6V
10.6V
120min.
——
120min.
120min.
OPERATING INSTRUCTIONS
FLOODED
LF1 (12V)
16.0V
14.6V
15.0V
14.8V
15.0V
14.8V
14.8V
——
14.6V
14.8V
13.8V
14.0V
13.2V
13.2V
12.6V
12.2V
12.2V
12.4V
12.0V
12.0V
11.1V
11.0V
10.6V
10.5V
120min.
——
120min.
120min.
LF2 (24V)
29.2V
28.8V
28.8V
——
28.8V
28.0V
26.4V
24.4V
28.8V
24.0V
22.0
21.0V
——
120min.

Advertisement