3. CHOOSING A BATTERY
The GP-PWM-30-DL is suitable for use with lead acid batteries (vented, GEL, or AGM type) as well as some lithium iron phosphate
(LiFePO4) batteries that are supplied with a Battery Management System (BMS). If using lithium ion, it must be lithium iron phos-
phate (LiFePO4) chemistry with a BMS. No other chemistries are compatible.
Lithium batteries usually have maximum allowed charge currents. These maximums typically decrease in cold temperatures. THE
GP-PWM-30-DL does not limit current for these restrictions, and system design of the solar array must account for this.
Be sure to follow all battery manufacturer safety instructions.
4. DURALITE KIT WIRING DIAGRAM
The GP-PWM-30-DL maximum 37.5A rating is based on a 30-amp total maximum short circuit current rating (Isc) from the solar
modules nameplate ratings. The National Electric Code specifies the PV equipment/system rating to be 125% of the maximum Isc
from the PV module ratings (1.25 times 30 = 37.5A). E.G. Three modules in parallel with an Isc of 7 amps each equal a total Isc
input of 21 amps. When selecting PV modules for use with the GP-PWM-30-DL, do not exceed a total nameplate Isc current of 30A.
Solar modules list the Isc amps on their nameplate label.
The controller will not work unless there is a battery connected to the Battery 1 terminals.
Note
WARNING: When the photovoltaic (solar) array is exposed to light, it supplies a dc voltage to this equipment.
DuraLite 100W Expansion Kit
Connect to
DC port of
Expansion
Kit
(Expansion Part #3)
Extension Cable
Solar Controller
(DuraLite Part #3)
DuraLite 100W Base Kit
3 Way Expansion Harness
(DuraLite Part #10)
Connect to DC
(Expansion Part #3)
Extension Cable
port of Base Kit
Connect
singular end
to connector
on solar
controller
DuraLite 100W Expansion Kit
Connect to
DC port of
Expansion
Kit
gpelectric.com | [page 7]