IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS
THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS FOR THE DURALITE KIT AND SOLAR CONTROLLER
THAT SHOULD BE FOLLOWED DURING KIT USE AND MAINTENANCE.
Read this manual in its entirety before using the DuraLite kit for the first time.
DO NOT GET WET. Bring in the DuraLite kit when it rains.
Use only with approved DuraLite connections and harnessing.
Please cut off all connections of the PV array, fuses or breakers which close to the battery before the controller installation and
adjustment.
Power connections should remain tight to avoid excessive overheating
No user serviceable component inside the controller. DO NOT disassemble or attempt to repair the controller.
[page 6] | gpelectric.com
Disconnect all power
Electricity can be very dangerous. Installation should be performed only by a licensed
sources
electrician or qualified personnel.
Observe all safety precautions of the battery manufacturer when handling or working
Battery and wiring
around batteries. When charging, batteries produce hydrogen gas, which is highly
safety
explosive. Ensure batteries are in a well-ventilated space, away from sparks for open
flames.
Wiring
Ensure all connections are tight and secure. Loose connections may generate sparks
connections
and heat. Be sure to check all connections before using the portable solar kit.
Wear protective eyewear and appropriate clothing during installation. Use extreme
Work safely
caution when working with electricity and when handling and working around batter-
ies.
Reverse polarity of the Battery 1 terminals will cause the controller to give a warning
tone. Reverse connection of Battery 2 terminals will not cause an alarm. However, the
Observe correct
controller will not charge or display information for Battery 2 on the LCD. The controller
polarity
will not function unless Battery 1 terminals are connected to a battery with proper
polarity. Failure to correct this fault could damage the controller.
Do not exceed the
The maximum current of the solar system is the sum of parallel-connected PV module–
Charge Controller
rated short circuit Currents (Isc) multiplied by 1.25. The resulting system current is
current and voltage
not to exceed 37.5A. If your solar system exceeds this value, contact your dealer for a
ratings
suitable controller alternative.
The maximum voltage of the array is the sum of the PV module–rated open-circuit volt-
Do not exceed max
age of the series connected modules multiplied by 1.25 (or by a value from NEC 690.7
voltage ratings
provided in Table 690.7 A). The resulting voltage is not to exceed 35V. If your solar
system exceeds this value, contact your dealer for a suitable controller alternative.