General Description
The P653S pump is designed for single line
(S) parallel Centro–Matic type lubrication
systems . The pumps integrated design
includes all necessary components to
support Centro–Matic lubrication systems:
• controller to program and monitor lubri-
cation cycle .
• internal pressure transducer .
• internal vent valve .
• three pumping elements connected
together .
• external pressure relief valve .
• reservoir low–level control .
• contacts for remote monitoring .
• 120/230 V AC power supply .Pump can
supply adequate lubricant to bearings us-
ing oil injectors SL–32, SL–33 SL–41,
SL–42, SL–43 and SL–44 . Number of in-
jectors should be based on output of the
pump being 1 .8 in
/min . (30 ml/min.)
3
Pump for 120/230 V AC power supply can be
installed in any stationary industrial type of
applications requiring lubrication for the
same number of medium size bearings .
!
Notice
Installations using SL–32 and
SL–33 Lincoln injectors can lubricate
more than 35 bearings .
Typical Centro–Matic system schematic
is shown on page 31.
!
Notice
Use only supply line hose and
fittings that are appropriate for the
programmed/set system pressure .
Pump P653S
• pumps mineral oil (per approved list) at
temperatures from
32 to 122 °F
min . 40 mm 2/s (CST)
(0 to 50 °C)
• develop maximum pressure up to
1,500 psi (100 bar) with pressure
transducer .
Reservoir sizes
• 4 l transparent plastic reservoir
• 8 l transparent plastic reservoir
Electrical connection
• For industrial 120/230 V AC applications
P653S pumps are provided with 4–pole
square type connector . Electric cable is
provided by installer .
7
Single–line pump P653S, no follower
(Note: Low–level control † fig. 12 and 13,
page 17)
2
1
11
10
9
1 Reservoir
2 Top lid
3 Stationary paddle
4 Stirring paddle
5 Mounting plate
6 Pump elements
7 Pump housing
8 Refill oil fitting
9 Keypad
10 Pump outlet
11 Relief valve
Fig. 1