Table of Contents

Advertisement

CHAPTER 5 TROUBLESHOOTING

5.4 Errors

E400
Cause
The combination cable between the DADF and the copier is faulty.
The ADF controller PCB is faulty.
Detection
While the DADF is in standby, the communication with the copier is dis-
rupted for 5 sec or more.
While the DADF is in operation, the communication with the copier is dis-
rupted for 0.5 sec or more.
E402
Cause
The belt motor (M2) is faulty.
The belt motor clock sensor (PI1) is faulty.
The ADF controller PCB is faulty.
Detection
When the belt motor drive signal is generated, no clock signal is detected
for 100 msec.
E404
Cause
The delivery motor (M5) is faulty.
The delivery motor clock sensor (PI11) is faulty.
The ADF controller PCB is faulty.
Detection
When the delivery motor drive signal is generated, no clock signal is de-
tected for 200 msec.
E405
Cause
The separation motor (M4) is faulty.
The separation motor clock sensor (PI2) is faulty.
The ADF controller PCB is faulty.
Detection
When the separation motor drive signal is generated, no clock signal is gen-
erated for 200 msec.
5-72
T05-504-01a
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON DADF-J1 REV.0 MAR.2001

Advertisement

Table of Contents
loading

Table of Contents