Tormach 35550 Technical Document

Tormach 35550 Technical Document

Mill enclosure door switch kit for pcnc 770 and pcnc 1100

Advertisement

TECHNICAL DOCUMENT
PCNC Mill Enclosure Door Switch Kit
Product Identification: Enclosure Door Switch Kit (PN 35550)
Purpose: This document details installation and use of the Enclosure Door Switch Kit on either a PCNC 770® or
PCNC 1100® mill.
Qty. Enclosure Door Switch Kit
Door Switch w/ Plate (attached to 10' of
1
2-conductor Wire)
1
Key w/ Plate
5
Mounting Tab
6
Cable Tie
5
10-32 Hex Nuts
4
10-32 x 7/16" Screw
1
Cord Grip
1
Cord Grip Nut
2
Wire Label (not shown)
1
Wire Cap
NOTE: If any of these items are missing, contact Tormach Customer
Service at (608) 849-8381 for a replacement.

Installation

1. Power off the mill according to the Power Off/On Procedure detailed below.
WARNING! Electrical Shock Hazard: Be sure to power off machine before making any electrical modifications.
Failure to do so may result in serious injury or death.

Power Off/On Procedure

1. Push red E-stop button in
Power Off
2. Click
Exit on screen; when prompted click OK to power off
3. Turn Main Disconnect Off (see image at right)
©Tormach® 2018. All rights reserved.
Specifications subject to change without notice.
TD10396_PCNC_EnclosureSwitch_0118A
PN
31460
31719
34101
32071
31376
31867
38543
Page 1
TORMACH.COM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 35550 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tormach 35550

  • Page 1 Wire Label (not shown) – Wire Cap 38543 NOTE: If any of these items are missing, contact Tormach Customer Service at (608) 849-8381 for a replacement. Installation 1. Power off the mill according to the Power Off/On Procedure detailed below.
  • Page 2 9. Route the 2-Conductor Wire through the Cord Grip assembly and pull enough wire through to reach electrical cabinet’s terminal block. Figure 2 ©Tormach® 2018. All rights reserved. Tormach, Inc. Specifications subject to change without notice. P: 608.849.8381 / F: 209.885.4534 TD10396_PCNC_EnclosureSwitch_0118A tormach.com...
  • Page 3 14. Move wire J2-1 to slot 4 (to the right) as shown in Figure 4. 15. Put the provided J2-4.1 decal on wire J2-1. J2-4.1 Decal Figure 4 ©Tormach® 2018. All rights reserved. Tormach, Inc. Specifications subject to change without notice. P: 608.849.8381 / F: 209.885.4534 TD10396_PCNC_EnclosureSwitch_0118A tormach.com...
  • Page 4 J2-4 and wire J2-4.2 are linked by an existing red jumper, as shown in Figure 6. From Door Switch Figure 6 ©Tormach® 2018. All rights reserved. Tormach, Inc. Specifications subject to change without notice. P: 608.849.8381 / F: 209.885.4534 TD10396_PCNC_EnclosureSwitch_0118A tormach.com...
  • Page 5 • To cap the spindle speed at 500 RPM with the door open, type ADMIN OPENDOORMAXRPM 500 in the MDI line on the Main tab. • To stop the spindle when the door opens, type ADMIN OPENDOORMAXRPM 0 in the MDI line. ©Tormach® 2018. All rights reserved. Tormach, Inc. Specifications subject to change without notice.
  • Page 6 Figure 9. Figure 9 Electrical Schematic J2-4.1 J2-4.2 X LIMIT Y LIMIT Z UPPER ©Tormach® 2018. All rights reserved. Tormach, Inc. Specifications subject to change without notice. P: 608.849.8381 / F: 209.885.4534 TD10396_PCNC_EnclosureSwitch_0118A tormach.com Page 6...

Table of Contents