11�3 Brivis Ad Winter Seal Installation - Rinnai brivis Contour Series Installation Manual

Table of Contents

Advertisement

11. INSTALLATION - BRIVIS AD
11.3 BRIVIS AD WINTER SEAL INSTALLATION
The Winter Seal can be fitted into the dropper duct before or after the dropper has been installed, but it is important 
to ensure that:
Dropper duct is square
The dropper duct seam and the large 45º fold-up corner are to the high side of the roof as shown in the drawing
below, otherwise the flaps will not open correctly.
The Winter Seal is level and a minimum of 120 mm down from the top of the dropper (150 mm maximum)�
On the inside surface of the dropper duct, measure and mark points 120 mm down from top of dropper in each
corner� Join the marked points, drawing four level horizontal lines on the inside of the dropper duct to provide
the height position to fix the Winter Seal.
Use pliers to bend fitting tabs on Winter Seal sides out at 45º, and bend up the large 45º fold-up corner.
Hold the Winter Seal by the solid corner (90º) and lower into dropper with small 45º corners aligned diagonally
across the dropper duct� Lower until small corners line up with marked lines� (See diagram below)
Rotate the fold-up corner up until the frame aligns with the marked lines allowing fitting tabs to jam tight against 
the dropper duct sides�
Check again that the large 45º fold-up is in the correct corner as per previous instructions�
45° Triangle Corners
Dropper Seam�
High side of roof
Align the top edge on the marked lines and drill through frame holes from inside to out� Pop rivet or screw from
outside to in, making sure screw or rivet tails do not interfere with the seal's operation�
Fitting tabs should be straightened before screwing or riveting.
NOTE
Route the cables through the
45º fold-up corner and bend the
45º corners down to seal� The
large fold-up should hold the
cable against dropper duct away
from the Winter Seal�
Ensure  flaps  on  Winter  Seal 
operate freely�
Brivis
Rotate up
when fitted.
120 mm Marks�
Dropper Box�
Cables should be
positioned in this
corner�
Position the larger 45°
fold-up corner so that
it will be under the
electrical box corner
of the cooler, where
the cables exit�
Solid Corner
Flap Pivots
Frame Holes�(Drill
from inside to out)�
22
Triangle Corners
Fitting Tabs�
To be bent at 45°�
45° fold-up corner�
(Bend down to seal
after cables have
been fed through)�
Align one of the small
45° corners with the
seamed corner of the
dropper�
Solid Corner
Evap AC IM