Check Valve (Solution Outlet); Chemical Pump - Prochem EVEREST LP Operating Instructions Manual

Table of Contents

Advertisement

MAINTENANCE

CHECK VALVE (SOLUTION OUTLET)

Inspect the check valve whenever doing service on
the chemical pump or if flow problems occur in the
chemical system:
1. Remove the check valve. Be sure the small o-
ring for the seat comes out with the check valve.
2. Remove the seat, using a 5/16" Allen wrench.
3. Check the Teflon seat for debris or wear. Clean
or replace Teflon seat if needed.
4. Clean the poppet and spring, inspect for wear or
damage, and replace as needed.
5. Re-assemble the check valve. Start the seat by
hand, tighten using a 5/16" Allen wrench. DO
NOT over-tighten seat.
Tight wrap
On spring
Use 5/16 Allen
Wrench to remove
NOTE: Improper seating of the check valve
poppet, damaged spring or o-rings will cause
poor operation of the chemical system.
6. Lubricate the o-rings with o-ring lubricant
Part #05-008035 and reinstall.
4-11

CHEMICAL PUMP

The only repairs which the chemical pump may
require is the replacement of the diaphragm or check
valves. To replace the diaphragm, unscrew the cover
from the body. When replacing the diaphragm,
lubricate the outer edges of the diaphragm with o-ring
lubricant Part #05-008035 and reassemble. To
replace the check valves, unscrew the check valve
caps. Replace the check valves and reassemble,
using new o-rings.
DO NOT attempt to re-use o-rings once the check
valves have been removed. See the "Illustrated
Parts Listing" for a parts break-down on the chemical
pump.
8
EVEREST 980086 02/18/03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Everest hp

Table of Contents