Summary of Contents for Prochem Ninja master 500 PSI NMCU2250H
Page 1
Ninja Master 500 PSI Extractor Operating Instructions (ENG) MODELS: NMCU2250H 10070770 From Serial Number (Ref No. 1*) * See Serial number page or call Manufacturer. 86399110-A 02/04/15...
Warranty Registration Thank you for purchasing a Prochem Kärcher Group product. Warranty registration is quick and easy. Your registration will allow us to serve you better over the lifetime of the product.
How To Use This Manual This manual contains the following sections: The SAFETY section contains important information regarding hazardous or unsafe practices of the • How to Use This Manual machine. Levels of hazards are identified that could • Safety result in product damage, personal injury, or severe •...
Safety IMPORTANT SAFETY INSTRUCTIONS When using this machine, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. To reduce the risk of fire, electric shock, or injury: Connect to a properly grounded outlet. See Grounding Instructions. Do not leave the machine unattended.
Safety The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions: WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
Safety Safety Labels NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them. Label, Warning 86244300 Label Circuit Interrupter 86200570 86399110 - Operators Manual - Ninja Master 500PSI...
Safety Grounding Instructions Grounding Pin THIS PRODUCT IS FOR COMMERCIAL GROUNDING CONNECTION USING AN ADAPTOR USE ONLY. Grounded Grounded Outlet Box Adaptor Outlet FIGURE A ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit. The amp, hertz, Metal Screw FIGURE B Adaptor...
Operations Only use chemicals approved for use with this machine. Use of non-compatible chemicals may cause machine damage and will not be covered under the Care must be exercised in the use of all chemicals. warranty. Carefully read ingredients on manufacturer’s Chemicals are poisonous and can pose a health risk.
Operations Pre-Run Inspection Heater Operation NOTE: Units with Heat Only 1. Check all fittings and connectors for proper assembly. 2. Check all hoses for leaks. Repair or replace any damaged hoses. The solution fittings on the machine will become extremely hot during operation. Allow sufficient 3.
Operations Cleaning Always use defoamer if foaming occurs. Foam will suspend large particles that may damage vacuum(s) as well as allow liquid into the vacuum motor(s) without activating the float shutoff. 1. Prior to cleaning, make certain that the nozzle is functioning properly.
Maintenance Periodic Maintenance Daily/Regular Maintenance Twice a month, flush a white vinegar solution (one quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the machine. This Before making any repairs or adjustments to the will prevent build-up of alkaline residue in the system. machine, disconnect the power cords from the electrical source.
Maintenance Vacuum Motor Carbon Brushes Replacement End Cap Only qualified maintenance personnel are to perform the following repairs. Carbon Vacuum Motor Replacement Brushes 1. Turn off all switches and unplug machine. WARNING: The 2. Remove hardware under front of machine to green ground wire access component compartment.
Maintenance Only qualified maintenance personnel are to perform the following repairs. Pressure Regulator For best results with the pressure regulator, we recommend that you clean and lubricate the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive. 1.
Maintenance Troubleshooting PROBLEM CAUSE SOLUTION Unit not plugged in Connect unit to 3 prong grounded outlet. Loss of Power Dead electrical circuit Check building circuit breaker or fuse box. Faulty power cord Replace Receptacle not grounded Contact an electrician to check building's wiring Electrical shock Have a trained service technician check Internal wiring problem...
Spare Parts List (1.007-0770) Ninja Master 500 PSI From Serial Number (Ref No. 1*) * See Serial number page or call Manufacturer. 86399120-A 02/02/15...
Page 23
How to Use this Spare Parts List The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information: • REF - column refers to the reference number on the parts illustration. •...
Page 24
Table of Contents How to Use this Spare Parts List ....2 Table of Contents ......3 Control Panel .
Heater TO CONSOLE SOLUTION FROM PUMP 86399120 Spare Parts List Ninja Master 500PSI...
Page 34
Heater SERIAL NO. PART NO. QTY DESCRIPTION NOTES FROM 86200260 HOSE,PULSE 47.0 1/4MPTX1/4MPT 86197360 ELBOW, 1/4 NPT STREET 86005810 NUT, 1/4-20 HEX NYLOCK SS 86273830 SCR, 1/4-20 X 1/2 HHCS SS 86233410 CLAMP, 3/4 DIA CUSHION .406 DIA 86010630 WASHER, 1/4 X 5/8 FLAT SS 86318310 CLAMP, 3.25 WORM GEAR SS 86318410...