CP Series Technical Manual
Adjuster Tube Setting
The adjuster tube is set by cutting and removing tabs on both sides of the tube.
Using a pocket-knife, cut across each tab horizontally, following the channel in
the plastic, and break off each tab individually until the proper setting is
reached. The remaining number or letter imprinted on the tab determines the
correct setting. The drawing at right shows an adjuster tube at setting "M".
Float Cup Setting
The float cup is set by adjusting its height above the bottom of the brine valve
assembly. By removing the brine valve assembly and resting it on a flat surface,
the height of the float cup can be measured with a ruler. The height is measured
from the base of the brine valve assembly to the top of the float cup (see drawing
at right). Note that standard settings are defined by markings on the rod of the
brine valve assembly. The settings on the rod are listed in the tables at the end of
this section. Where the predefined settings are not adequate, the actual float cup
height, in inches, is listed, and the setting must be measured and set according
to the measured float cup height.
24 x 40 Brine Drum Valve Adjustment
Salt
Setting
15 LBS
25 LBS
Adjuster
Tube
1.25
K
Float
Cup
10.5 in.
12 in.
Page - 18
30 LBS
40 LBS
N
N
11 in.
16 in.
Installation
The CP units require the Adjuster
Tube and float cup to be set.
Float
Cup
Setting
Float
Cup
Setting
December 15, 2004