KINETICO PREMIER RO Owner’s Manual Model/Product Number: Kinetico Premier RO (100-0006)
Page 3
Kinetico water treatment system. Since 1970, Kinetico Incorporated has designed and manufactured products to improve the quality of your water. Kinetico offers a complete line of quality water systems to solve your water problems. Pioneers in non-electric, demand operated water treatment, Kinetico continually sets the direction for the entire water quality industry.
Table of Contents Before using your equipment Getting to know your equipment How to install your Premier RO Instructions for use Maintaining your Premier RO System Specifications Troubleshooting Kinetico Denmark ApS Kinetico Canada Incorporated Kinetico Incorporated Sandvadsvej7 21 Parr Blvd., Unit 10 10845 Kinsman Rd.
Before using your equipment Read all safety information and follow the instructions described in this Owner’s Manu- al prior to installing and using the Premier Reverse Osmosis equipment. It is important that before installation and setup, you check the box and the condition of the equipment, in order to guarantee that it has not been damaged during trans- port.
Page 6
• Before use, please make sure that the voltage supplied is correct. Only use the origi- nal power adapter and verify that there is no damage to the power cord or plug. Re- gularly check that there are no loose wires or damage to the power supply. In case of any damage, do not continue to use the water purifier, and immediately contact your dealer for testing and repair.
Getting to know your equipment Main unit 1/4” clip CF filter 3/8” PE tube (white) Front cover T-ball valve RO Membrane 1/4” PE tube (white) 3/8” clip 1/4” PE tube (red)
How to install your Premier RO Read all safety information and follow the instructions described in this Installation and User Manual prior to installing and using the Premier Reverse Osmosis equipment. Location of the equipment: 1. This equipment should not be installed lying down or tilted, as the leak sensor could be disabled.
Page 9
Confirm that you have all the items indicated in the packing list: Image Remark No.I temQ Quantity Main unit CF Filter RO Membrane Front panel 3-way connector Includes: accessory pack 1 pc T-Ball valve 1 pc 3/8” clip 2 pcs 1/4” clip 1/4”...
Page 10
Installation steps: 1. Close the cold water valve and remove the cold water hose from the valve. 2. Install the female end of the T-ball valve on the cold water valve and tighten it with a wrench (do not miss the sealing gasket on the T-ball valve when installing). 3.
Page 11
6. Filter installation: Remove the plastic wrap and protective cap of each filter. Place Filter 1 in the upper position, and Filter 2 in the lower position indicated in Figure 9. To properly install the filters, insert each filter all the way in its respective hou- sing with the handle in a horizontal position, and once the filter cannot be pushed further in, turn the handle 90 degrees clockwise, as indicated in Figure 9.
Page 12
8. Connect the loose end of the 3/8” PE tube to the Inlet water outlet on the unit with the 3/8” clip, as shown in Figure 11. 9. Connect one end of the 1/4” red PE tube to the Waste water outlet on the unit with the 1/4”...
Page 13
10. Connect one end of the 1/4” white PE tube to the Pure water outlet on the unit with the 1/4“ clip, with the other end of the white PE tube connected to the faucet with a 1/4” clip, as indicated in Figure 13 (faucet and corresponding clip are sold separately). 11.
Instructions for use Once the unit is properly installed and before drinking the water produced by the Premier Reverse Osmosis equipment for the first time, it is necessary to eliminate the loose carbon dust that is generated during the transport and handling of the cartrid- ges.
Page 15
• Other status indicators: − First power on: after powering on the unit, the unit will beep and the various dis- play lights will illuminate at the same time, flashing 1 second through the various states (blue-purple-red), and 3 seconds on the monochrome lamp. −...
Maintaining your Premier RO equipment Some components of your system have a limited life span and will need to be replaced. The precise duration will depend on the quality of the local water, the total amount of water consumed, the pattern of usage, and specific characteristics of the water to be treated such as high chlorination or excess hardness, etc.
System specifications Model Kinetico Premier RO 800 Cabinet dimensions 415 x 155 x 485 mm (height x width x depth) Power usage 100 W Output DC36V Power supply 220V (187V ~ 242V) / 50Hz 11.5 kg Net weight Operating pressure 0.42 - 0.8 MPa...
Troubleshooting Failure Causes Solutions 1. Check if the PE tube is broken 1. Replace PE tube 2. Check if the PE tube is inserted in 2. Reinsert PE tube place 3. Recut PE tube 3. Check if the PE end has been out flat Water leakage Confirm if the filter Reinstall the filter cartridges...
Need help?
Do you have a question about the Premier RO and is the answer not in the manual?
Questions and answers