This document will guide the installer through the process of installing, configuring, and adding a Savant SmartControl 12 Controller to a RacePoint Blueprint®
Page 1
Document Date: June 2021 Document Supports: da Vinci 7.0 and higher This document will guide the installer through the process of installing, configuring, and adding a Savant SmartControl 12 Controller to a RacePoint Blueprint® configuration. – SmartControl 12 Controller [SSC-0012]...
Unique ID (UID) of the controller ......................................... (located on the bottom of the unit) Savant Host (Smart or Pro Host) licensed and running da Vinci 7.0 or higher ......................Savant Development Environment (SDE/MacBook®) ................................(with RacePoint Blueprint da Vinci 7.0 or higher installed) Ethernet network meeting Savant requirements ...................................
2. Deployment Steps To successfully deploy a Savant Rack Mountable Host, follow the steps listed below. This page can be used as a checklist to track progress as items are completed. Review the SSC-0012 Connections and Controls and Mount Controller ........................
Plug the supplied power supply from the 12V DC port into a 120V AC surge protected outlet. 4.2. Control Connections Information on wiring the IR, RS232, and GPIO control connections are available in the Savant SmartControl 12 [SSC-0012] Quick Reference Guide on the Savant Customer Community.
Drag the SSC-0012 into Blueprint's layout window. Select the SSC-0012 and open the inspector. View > Show Inspector Enter the Unique ID of the SSC-0012 into the Savant UID field. See image below. UID can be found on the label on the bottom of the device.
Optional: Select Update All UI Screens > Sync with Services (only if necessary) from the Blueprint toolbar to sync any TrueControl II interfaces to the services. The State icon will change to green when complete. Select the Upload to Master icon from the Blueprint toolbar and answer the prompts to upload the configuration to the Savant Pro System Host. Select Upload to Master The System Monitor application will automatically open as displayed in the image below.
Network Changes Savant recommends performing the following steps to refresh the IP connection after connecting to a new network, changing routers, or if the IP Address range is changed in the current router. This will reset any IP connection and ensure that the Host is communicating with the network correctly.
Page 10
Savant Systems, Inc. shall not be liable for any technical or editorial errors or omissions contained herein or for incidental or consequential damages resulting from the performance, furnishing, reliance on, or use of this material.
Need help?
Do you have a question about the SmartControl 12 and is the answer not in the manual?
Questions and answers