Viessmann VITODENS 300 Service Instructions Manual page 76

Wall mounted gas fired condensing boiler. natural gas and lpg version. 4.2 to 13.0 kw
Hide thumbs Also See for VITODENS 300:
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Display
Const.
Weath.-
fault
comp.
code
92
X
X
9A
X
X
93
X
X
9B
X
X
94
X
X
9C
X
X
9F
X
X
A7
X
b0
X
X
b8
X
X
76
System char-
Cause
acteristics
Control mode
Solar: Col-
lector tem-
perature
sensor
shorted out
Control mode
Solar: Col-
lector tem-
perature
sensor lead
broken
Control mode
Solar: Sen-
sor S 3
shorted out
Control mode
Solar: Sen-
sor S 3 lead
broken
Control mode
Solar: Cylin-
der tempera-
ture sensor
shorted out
Control mode
Cylinder
temperature
sensor lead
broken
Control mode
Solar control
unit fault
message
Control mode
Faulty pro-
gramming
unit.
Burner
Flue gas
blocked
temperature
sensor
shorted out
Burner
Flue gas
blocked
temperature
sensor break
Remedy
Check sensor.
Check sensor.
Check sensor.
Check sensor.
Check sensor.
Check sensor.
See solar control
unit service in-
structions.
Replace program-
ming unit.
Check the flue
gas temperature
sensor (see page
87).
Check the flue
gas temperature
sensor (see page
87).