Viessmann VITODENS 300 Service Instructions Manual page 75

Wall mounted gas fired condensing boiler. natural gas and lpg version. 4.2 to 13.0 kw
Hide thumbs Also See for VITODENS 300:
Table of Contents

Advertisement

Fault codes
(cont.)
Display
Const.
Weath.-
fault
comp.
code
38
X
X
40
X
48
X
50
X
X
58
X
X
51
X
X
59
X
X
System char-
Cause
acteristics
Burner
Boiler water
blocked
temperature
sensor lead
broken
Mixer closes.
Mixer circuit
M2 flow tem-
perature
sensor
shorted out
Mixer closes.
Mixer circuit
M2 flow tem-
perature
sensor lead
broken
No DHW heat-
Cylinder
ing
temperature
sensor/com-
fort sensor/
primary sen-
sor shorted
out
No DHW heat-
Cylinder
ing
temperature
sensor/com-
fort sensor/
primary sen-
sor lead bro-
ken
No DHW heat-
Cylinder
ing
temperature
sensor 2
lead broken
No DHW heat-
Cylinder
ing
temperature
sensor 2
lead broken
Troubleshooting
Remedy
Check the boiler
water tempera-
ture sensor (see
page 85).
Check the flow
temperature sen-
sor.
Check the flow
temperature sen-
sor.
Check sensors
(see page 85).
Check sensors
(see page 85).
Check sensors
(see page 85).
Check sensors
(see page 85).
75