Viessmann VITODENS 300 Service Instructions Manual page 57

Wall mounted gas fired condensing boiler. natural gas and lpg version. 4.2 to 13.0 kw
Hide thumbs Also See for VITODENS 300:
Table of Contents

Advertisement

Code 2
(cont.)
Parameter ad-
With heating circuit pump logic function: Heating cir-
dress b5:...
cuit pump OFF, if
3:
enabled RT
4:
enabled RT
5:
enabled RT
6:
enabled RT
7:
enabled RT
8:
enabled RT
Coding in the delivered condition
Boiler circuit, mixer circuit
*
1
C5:20
Electronic minimum
flow temperature limit in
standard mode 20 °C
*
1
C6:74
Electronic maximum
flow temperature limit
74 °C
*
d3:14
1
Heating curve slope =
1.4
*
1
d4:0
Heating curve level =
0
*
1
d5:0
The heating program
changes to "Constant
operation with reduced
room temperature"
*
1
E1:1
With remote control:
Set day temperature is
adjustable at the remote
control unit from 10 to
30 °C
*1
Only for weather-compensated control units.
> RT
+ 3 K; disabled RT
actual
set
> RT
+ 2 K; disabled RT
actual
set
> RT
+ 1 K; disabled RT
actual
set
> RT
; disabled RT
actual
set
> RT
- 1 K; disabled RT
active
set
> RT
- 2 K; disabled RT
actual
set
Possible change
C5:1
to
C5:127
C6:0
to
C6:127
d3:2
to
d3:35
d4: 13
to
d4:40
d5:1
E1:0
E1:2
Coding
< RT
+ 2 K
actual
set
< RT
+ 1 K
actual
set
< RT
actual
set
< RT
- 1 K
actual
set
< RT
- 2 K
actual
set
< RT
- 3 K
actual
set
Minimum temperature
limit in standard mode
adjustable from 1 to
127 °C
Maximum temperature
limit adjustable from 1 to
127 °C
Heating curve slope ad-
justable from 0.2 to 3.5
(see page 33)
Heating curve level ad-
justable from 13 to 40
(see page 33)
The external heating pro-
gram changeover
changes to "Constant
central heating with stan-
dard room temperature"
Set day temperature ad-
justable from 3 to 23 °C
Set day temperature ad-
justable from 17 to 37 °C
57

Advertisement

Table of Contents