The Culligan
microprocessor can be indexed through the various regeneration steps. For all steps, the cycle numbers do not
®
appear, or change, until the motor stops.
1.
Press the status button to move past the programming steps until the display is
blank. From blank display press the "+" key. An "H" will appear in the display.
The control is in the HOME position.
2.
Press and hold the regen button. The 'REGEN' icon will blink, and the motor
will advance the control. A '1' will appear. The unit is now in the BACKWASH
position. The numbers to the right indicates the time remaining for the cycle.
3.
Press the "+" key. A '2' will appear in the display, along with the cycle time
remaining. The control is in the PAUSE cycle.
4.
Press "+" key. A '3' will appear in the display, along with the cycle time
remaining. The control is now in the FAST RINSE cycle. Note: The time
displayed is rounded down to the closest minute.
5.
Press the "+" key. An 'H' will appear in the display. The unit is in the HOME
position. The 'REGEN' enunciator is no longer blinking.
6.
Press the status key. Time-of-Day appears in the display.
Note: If the "+" key is pressed to cycle the value from position "3" to "Home",
the # regen counters will not be updated.