Mount the Control Valve - 1" Controls
Assemble the control valve to the media tank as follows, See Figure 8
1.
Assemble the o-rings, located in the parts pack, to the tank
adapter.
2.
The valve adapter o-ring sits on the first step on the adapter. See
Figure 9.
Note: Do not push the top o-ring down to the flange surface on the
adapter.
NOTE: The larger of the two o-rings in the parts part goes between
the adapter and the valve, do not stretch the smaller o-ring onto the
top of the tank adapter.
3.
Lubricate only the top o-ring on the tank adapter, and the outlet
manifold o-ring with silicone lubricant.
4.
Screw the adapter into the tank until the adapter bottoms out on
the tank flange.
Note: The adapter only needs to be tightened hand-tight to
the tank flange. Make sure strainer is threaded into tank until it
bottoms out or interference with adapter may result.
5.
Align the manifold with the center opening in the valve, and press
the valve onto the adapter firmly.
Note: Make sure to push the valve straight down onto the
manifold. If the valve is cocked, it may cause the o-ring to slip off
the manifold.
6.
Assemble the tank clamp to the control, and tighten the clamp
screw.
Note: The clamp and valve will be able to rotate on the tank until
pressure is applied. Do not try to rotate control valve if the clamp is
tightened - you may cut the o-ring
Install the Flow Control
As shipped from the factory, each control is equipped with a 2 gpm flow control for 8" Cullar
included with each unit for conversion for use with other filter tanks. Refer to Table 1 to select the proper flow control.
Note: To prevent injury, convert units to the proper flow control prior to installation.
Table 1
Filter
8" Cullar
10" Cullar
8" Cullneu
®
10" Cullneu
8" Filtr-Cleer
10" Filtr-Cleer
* Use with flow control spacer provided
®
Figure 9
Flow Control
2.0 gpm
6.0 gpm
3.5 gpm
6.0 gpm
4.5 gpm
7.0 gpm*
Figure 8
®
filters. Additional flow controls are
Color
Brown
Black
Green
Black
Red
Black (Thin)