Plumbing Connections - 1" Controls
Shipped with each softener is a Culligan
bypass allows the softener to be isolated from the water service line if service is necessary while still providing water to the home.
The bypass valve can be directly plumbed into the system, or can be connected with the following optional sweat connection kits:
Part No.
01010783
01016564
01016565
Caution! Close the inlet supply line and relieve system pressure before cutting into the plumbing! Flooding could
result if not done!
Caution! When making sweat connections, use care to keep heat away from the plastic nuts used to connect the
plumbing to the bypass. Damage to these components may result otherwise.
Bypass Valve Installation
The bypass valve connects directly to the control valve with a
pair of couplings and two assembly pins (Figure 13). Lubricate
all o-rings on the couplings with silicone lubricant.
Note: If the ground from the electrical panel or breaker box
to the water meter or underground copper pipe is tied to the
copper water lines and these lines are cut during installation
of the bypass valve, an approved grounding strap must be
used between the two lines that have been cut in order to
maintain continuity. The length of the grounding strap will
depend upon the number of units being installed. In all cases
where metal pipe was originally used and is later interrupted
by the bypass valve to maintain proper metallic pipe bonding,
an approved ground clamp c/w not less than #6 copper
conductor must be used for continuity. Check your local
electrical code for the correct clamp and cable size.
To bypass, turn the blue knob clockwise (see directional arrow on end of knob) until the knob stops as shown. DO NOT
OVERTIGHTEN! (Figure 14a).
To return to service, turn the blue knob counter-clockwise (see directional arrow on the end of knob) until the knob stops as
shown. DO NOT OVERTIGHTEN! (Figure 14b)
Figure 14a
®
bypass valve, which is used to connect the softener to the plumbing system. The
Description
1" Sweat copper adapter kit
3/4" Sweat copper adapter kit
3/4" Elbow sweat copper adapter kit
Assembly Pin
Coupling
Bypass
Figure 13
Figure 14b
Brine
Connection
Coupling
Assembly
or Meter Body
Pin
About 1-1/4"
A screwdriver shank may be
used in the slot as a lever for
extra turning force if needed.
Installation
12