Programming
Make sure the inlet water supply is turned off, then supply power to the timer. The display will power up flashing "12:00 PM" and
the motor will energize and cycle the control, without stopping, to the home position. This is required to ensure that the control is
in the home position.
The timer uses four buttons:
1.
STATUS Advance timer through display options.
2.
PLUS SIGN "+"
Increase the setting.
3.
MINUS SIGN "-" Decrease the setting.
4.
REGEN Initiate a manual regeneration.
Programming the Option Settings
The microprocessor has several programming options that can be changed for various additional functions. Listed are the
functions for the programming options used on the Culligan Medallist Series control.
Dip Switch
1
2
3
4
5
6
IMPORTANT: The Medallist control is shipped from the factory in the softener mode. The program setting must be
changed from the softener mode to the filter mode - see step number 3.
1
Service or Test Mode
Press and hold the "STATUS" key until "dIP1" appears in the display. "dIP1" will
blink for 3 seconds and then the display will show the status of this option (SEr
or tES). Toggle the feature with the "+" or "-" key.
Note: Pressing "STATUS" after changing option to test mode will place the
control in test mode. After testing is complete press and hold "STATUS" for 3
seconds to return to service. Placing the unit in test mode will not change any of
the programmed values (Refer to the service manual for test menu).
2
Delay or Immediate Regeneration
Press the "STATUS" key. The display will blink "dIP2" for 3 seconds and then
show the current status. Toggle between "DEL" (Delay) and "Id" (Immediate)
with the "+" or "-" key.
Note: Changing this setting will not change any of the programmed value with
the exception that Step #2, time of regeneration will be ignored when set to
immediate.
3
Softener or Filter
Press the "STATUS" key. The display will blink "dIP3" for 3 seconds and then
show the current status. Toggle between "SOF" (Softener) and "FIL" (Filter) with
the "+" or "-" key.
Note: Changing this setting will cause the unit to load the Filter or Softener
defaults.
15
Culligan Medallist Series
Function
Service or Test
Delay or Immediate Regeneration
Softener or Filter
Time Clock Backup
English or Metric
3/4" or 1" Meter
®
Water Filters
Figure 16 - Circuit Board Display
Default Position
Service
Delayed Regeneration
Softener
OFF
English
3/4" Meter
DEL
F IL