Filling Procedure - Culligan Medallist Series Installation And Operation Instructions With Parts List

Hide thumbs Also See for Medallist Series:
Table of Contents

Advertisement

®
Filtr-Cleer
Water Filter
The 8" Filtr-Cleer filters are shipped with one media pack and the 10" Filtr-
Cleer filters are shipped with two media packs. Verify that the proper number
of media packs are on site before loading the tank. Place the manifold inside
the tank. Position the tip of the manifold in the recess located in the bottom
of the tank.
Cover the top of the manifold with a clean rag.
Place a wide-mouth funnel in the tank opening.
Open the media pack(s) by cutting along the bottom of the carton and
lifting up to expose the four individual media packages (Figure 3).
Note: The performance of the filter may be severely affected if the
media is not added in the proper sequence shown.
With no water in the tank, slowly pour the Cullsan
Note: The 10" filter uses only one bag of Cullsan U media pack. Shake
tank to level the media.
With no water in the tank, slowly pour the Cullsan G-50 media into the tank and level.
Note: The 10: filter requires the Cullsan G-50 from both of the media packs.
With no water in the tank, slowly pour the Cullsan A media into the tank and level.
Note: The 10" filter requires the Cullsan A from both of the media packs.
Slowly pour the Cullcite
Note: The 10" filter requires the Cullcite from both of the media packs.
®
Cullar
Filters
Cullar filters are shipped with one cubic foot of carbon and a 20 lb bag of Cullsan underbedding. Verify that the proper amount of
media is on site before loading the tank.
Place the manifold inside the tank. Position the tip of the manifold in the recess located in the bottom of the tank.
Cover the top of the manifold with a clean rag.
Place a wide mouth funnel in the tank opening.
Open the bag of Cullsan underbedding. On 8" Cullar units, slowly pour approximately half the contents of the bag into the
tank. On 10" Cullar units, pour the entire contents into the tank. Shake the tank to level the media.
Open the bag of carbon. On 8" Cullar units, slowly pour the carbon into the tank via the funnel until the carbon is within 13"
- 14" of the top of the tank. On 10" Cullar units, slowly pour the entire contents of the bag into the tank. Shake the tank to level
the media.
Remove the rag from the manifold.
Fill the tank with water and allow the media to soak for 24-48 hours. The water level in the tank will decrease as the media
soaks up water. Add water to the tank to keep the media submerged so all of the media gets saturated.
®
Cullneu
Filters
Cullneu filters are shipped with 2 bags of Cullneu with 8" filters and 3 bags of Cullneu with 10" filters. Verify that the proper amount
of media is on site before loading.
Place the manifold inside the tank. Position the tip of the manifold in the recess located in the bottom of the tank.
Cover the top of the manifold with a clean rag.
Place a wide mouth funnel in the tank opening. The Cullneu media should be added with no water in the tank.
For 8" Cullneu filters, slowly pour the entire contents of one bag of media and enough media from the second bag to raise the
level of media in the tank to within 11" of the top of the tank.
For 10" Cullneu filters, slowly pour the entire contents of two bags of media and enough media from the third bag to raise the
level of media in the tanks to within 21" of the top of the tank.
DO NOT OVERFILL. Overfilling will result in excess media being lost to drain during backwash, possibly plugging the
control valve. Shake the tank to level the media.
®
®
media into the tank and level.
media into the tank.

Filling Procedure

Figure 3
Filling Procedure
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents